Hepa Filter Replacement; Tightness Inspection; Disposing Of The Vacuum Cleaner; Wiring Diagram List - Blastrac BDC1330 DBP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Operating manual BDC1330 DBP/LPP

HEPA filter replacement

Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
1.
Vacuuming unit
2.
Locking lever
3.
Absolute filter lock ring
4.
Absolute filter disc
5.
Absolute filter
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
Unscrew ring (3).
Pull out disc (4) and absolute filter (5).
Place absolute filter (5) in a plastic bag, close the bag
hermetically and dispose of the filter in accordance with
the laws in force.
Insert a new filter (5) with the same filtering
characteristics as the removed one.
Lock the absolute filter with disc (4) and tighten ring
(3).
Replace vacuum unit (1).
Fix the vacuuming unit using the lever (2).
GB
WARNING!
Figure 10
WARNING!

Tightness inspection

Hoses check
Make sure the connecting hoses (Fig. 12) are in a good
condition and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle plate
inside the filtering chamber.
Scrape inlet (2 - Fig. 12) from the outside and remove the
deposited waste as indicated in figure 12.
Filtering chamber tightness check
If gasket (1 - Fig. 13) between container (4) and filter
chamber (3) fails to guarantee a good seal:
Loosen the four screws (2) that lock the filtering
chamber (3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and tighten
the screws (2) once it has reached the tightness position.
If an optimal seal cannot be obtained and the gasket is torn
or cracked, etc. it must be replaced.

Disposing of the vacuum cleaner

Figure 14
Dispose of the vacuum cleaner in compliance with the laws
in force.
Proper disposal (electric and electronic waste).
(Applicable in the European Union and in
countries providing a separate collection system)
The above symbol (Fig. 14), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damage to the environment or health caused by
improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reutilisation of material resources.
This product can not be disposed of together with other
commercial waste.

Wiring diagram list

Figure 15
1.
Compressor
2.
Motor head
Q1.
Main switch
TS2.
Cyclic timer
TR1.
Transformer
M1.
Clamp
XC1.
SCHUKO socket
XC2.
Connector
12/14
info@blastrac.eu

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bdc1330 lpp

Tabla de contenido