22
A perforated basket is required for filter systems without a pre-filter! Ensure
that the pre-filter or screen basket is not completely clogged with dirt. Remove
the contaminants that have been sucked in in the meantime. If the suction power
decreases, stop work immediately and clean the filters! The system must be
subsequently backwashed each time the floor is cleaned!
Important: Always switch off the pump before moving the valve from one position to
the next.
FILTRATION Adjusting the handle position for filtration – Normal operating position.
The pool water flows through the sand filter and returns to the pool cleaned. Use this
position even when cleaning the base.
BACKWASH Adjusting the handle position for backwashing – The water flows in the
opposite direction through the sand filter and is drained via the drain connection. Min.
once per week for 3–5 minutes and after each floor cleaning procedure.
RINSE Adjusting the handle position for rinsing – For performing residual cleaning
and re-compacting the filter material. The water is drained via the drain connection.
Duration: approx. 30 seconds. Perform after each backwashing process.
WINTER Adjusting the handle position for winter (to be done from autumn onwards)
– The valve is open to relieve the pressure on the gaskets.
Cleaning, maintenance and storage
Maintain and clean the kit regularly to ensure performance and long life.
Do not carry out any work on the unit that is not described in this manual yourself;
leave it to a specialist instead. Only use original parts.
Make absolutely sure that the mains plug is pulled out before any work is performed on
the unit. Otherwise, there is considerable risk of electric shock or injury due to moving
parts.
Clean the pump regularly with clean water.
Storage
Clean the kit before storage.
Store the kit in a dry and frost-proof area, out of the reach of children.
If you intend to store the pump for an extended period of time, you must clean
the unit thoroughly after the last operating session and before using it again.
Otherwise, start-up difficulties may occur due to residues or deposits.
All other work, especially opening the pump, should only be carried out by a qualified
electrician.
www.DeubaXXL.de
Functions
Troubleshooting
Warning: disconnect the pump from the power supply first before taking any action.
Problem
Cause
Pump with no action
No power available
Pump works audibly, but no
1.Air in system (pump/tank)
water is flowing
2.Hoses kinked, pump is taking
in air
3.Suction height too high,
incorrect suction hose
Low-flow rate
1.Suction/delivery height
exceeded
2.Valve/hose/filter dirty
Pump stops suddenly
Overheating has triggered the
thermal switch
Heightened pressure
1.Blockage
2.High contamination
23
Solution
Insert plug or check fuses if
necessary
1.Ventilate the pump as
described and if necessary also
the tank.
2.Check and, if necessary,
correct and seal straightened
connections. Possible hose leak
3.Adjust the position of the
pump Use vacuum-safe suction
hose
1.Adjust the position of the
pump/system
2.Check and clean if necessary
Use a vacuum-safe suction hose
-wait approx. 30 minutes
-use vacuum-safe suction hose
-check clogged pipes