CODING
PRODUCT
DFRA / DFLEX
SERIES
DFRA-
0100
0130
0160
0175
0200
0230
0300
0400
0500
0650
MODEL
0900
REACTIVATION SYSTEM
E
=
Electric coil
A
=
Coil for hot water
S
=
Hot Water coil + electric coil
V
=
Coil for saturated steam
H
=
Stainless steel coil for saturated steam
D
=
Saturated steam coil + electric coil
X
=
Stainless steel coil for saturated steam+ electric coil
G
=
Gas with Flame in reactivation air flow
I
=
Gas (Combustion flow separated only for American market)
PROCESS AIR FILTERS
00
=
Without filters
G0
=
1 Filters stage class G4 (EN779:2012)
GF
=
First stage class G4 filters and second stage class F9 (EN779:2012)
C0
=
1 stage of filters of a specific class other than G4 (EN779:2012)
0F
=
1 Filters stage class F9 (EN779:2012)
CC
=
Two stages of filtering other than G4F9(EN779:2012)
REACTIVATION AIR FILTERS
00
=
Without filters
G0
=
1 Filter stage class G4 (EN779:2012)
GF
=
First stage class G4 filters and second stage class F9 (EN779:2012)
C0
=
1 stage of filters of a specific class other than G4 (EN779:2012)
0F
=
1 Filter stage class F9 (EN779:2012)
CC
=
Two stages of filtering other than G4F9(EN779:2012)
PRE-HEATING
00
=
No pre-heating
WE
=
ECO pre-heating coils for hot water.
WS
=
STANDARD pre-heating coil for hot water.
WH
=
Water High Power Heating Coil
CW
=
Custom pre-heating coil
PRE-COOLING
00
=
No pre-cooling
WE
=
ECO pre-heating coil for cold water.
WS
=
STANDARD pre-cooling coil for cold water.
WH
=
High-power pre-cooling coil for cold water.
DS
=
STANDARD pre-cooling coil for direct expansion.
CW
=
Custom pre-cooling coil
POST-COOLING
00
=
No post-cooling
WE
=
ECO post-cooling coil for cold water.
WS
=
STANDARD post-cooling coil for cold water.
WH
=
High-power post-cooling coil for cold water.
DS
=
STANDARD post-cooling coil for direct expansion.
CW
=
Custom Post-cooling coil
POST-HEATING
00
=
No post-heating
WE
=
ECO post-heating coil using hot water.
WS
=
STANDARD post-heating coil using hot water.
WH
=
Water High power heating Coil
CW
=
Custom Post-Heating coil
PROCESS AIR / DRY AIR FAN
00
=
No process/dry air fan
SF
=
STANDARD fan
PF
=
POWERED fan
PS
=
Plug-Fan for DFRA serie
PP
=
Multiple Plug-Fan (Wall-Fan)
PT
=
Multipl Plug Fan (Tandem Plug-Fan)
REACTIVATION AIR / MOIST AIR FAN
SF
=
STANDARD fan
PF
=
POWERED fan
DRY AIR FILTER
000  
=
Without final filter at dry air.
F00
=
Class F9 EN 779: 2012 /ePM1 80< ISO16890. Filter fitted after the process air/dry air fan (requires a Plug-Fan ventilator)
H13
=
HEPA H13 (EN 1822:2011) filter fitted after the process air/dry air fan (requires a Plug-Fan ventilator)
H14
=
HEPA H14 (EN 1822:2011) filter fitted after the process air/dry air fan (requires a Plug-Fan ventilator)
FH3
=
Class F9 EN 779: 2012 /ePM1 80< ISO16890 + HEPA H13 (EN 1822:2011). Filter fitted after the process air/dry air fan (requires a Plug-Fan ventilator)
FH4
=
Class F9 EN 779: 2012 /ePM1 80< ISO16890 + HEPA H14 (EN 1822:2011). Filter fitted after the process air/dry air fan (requires a Plug-Fan ventilator)
SENSITIVE HEAT RECOVERY UNIT
0
=
Without heat recuperator. No by-pass in desiccant rotor.
R
=
Static heat recuperator installed in the discharge of wet air.
D
=
By-pass air damper in descending rotor.
M
=
Static heat recuperator installed in the discharge of wet air. By-pass air damper in descending rotor.
FINISHING
00
=
Standard production of components. Protection grade IP50 and finished with RAL7035 colour.
0R
=
Standard production of components. Protection grade IP50 and finished with specific colour (RAL____).
K0
=
Standard production of components. Protection grade IP54 and finished with RAL7035 colour.
KR
=
Standard production of components. Protection grade IP54 and finished with specific colour (RAL____).
Rev 01-01-2021
DFRA-0900
E
DFLEX
1100
1300
1700
2100
2900
3500
GF GF
WS
WS WS WS
SF
SF
H14
R
KR
405
AE04
0