• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury,
or property damage. Be sure all air is out of the system before operating.
Jandy
pool equipment is pressure tested at the factory. Local codes may require the pool piping system to be
®
subjected to a pressure test. BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and
secured before testing.
• RELEASE ALL AIR in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
NOTICE: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult equipment
manufacturer.
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to
fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.
Do not start pump dry! Running the pump dry for any length of time will cause severe damage and may void the
warranty.
This pump is for use with permanently installed pools and may also be used with hot tubs and spas, if so marked.
Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building
such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily
disassembled for storage and reassembled to its original integrity.
Do not install within an outer enclosure. The pump requires adequate ventilation to maintain air temperature at
less than the maximum ambient temperature rating listed on the motor rating plate.
In order to avoid premature failure or damage to the pump motor, protect the pump from direct water exposure
from sprinklers, water runoff from rooftops and drainage, etc. Failure to comply may cause pump failure, and may
also void warranty.
SUCTION HAZARD. Can cause serious injury or death. Do not use this pump for
wading pools, shallow pools or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets.