Cleaning With Detergents; Shutdown - Mi-T-M GP Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS

CLEANING WITH DETERGENTS:

.  Prepare detergent solution according to label directions.  Never pump 
acids, alkaline, abrasive fluids or solvents through the unit.
2.  Some units are equipped with adjustable detergent knobs.  Locate the 
clear vinyl hose which leads to the pump head. 
a.  If your injector is equipped with an adjustment knob on the pump 
head, you may adjust the amount of detergent desired by turning 
the knob completely counterclockwise to set at the maximum siphon 
rate.
b.  If your injector is not equipped with an adjustment knob, the detergent 
ratio is preset and cannot be adjusted.
3.  Fully immerse the detergent strainer into the detergent solution.
4.  With the trigger gun locked in the "OFF" position, securely quick-connect 
the detergent spray nozzle (#6540° BLACK) into the end of the wand.
NOTE: This injection system is designed to apply detergents under low
pressure only. It will not allow detergent solutions to be introduced
into the system unless the detergent nozzle assembly installed in
the wand.
5. To apply solution; unlock the trigger gun and squeeze the trigger. In a
few moments a detergent/water mixture will exit the low pressure nozzle.   
Start spraying the lower portion of the surface being cleaned and move 
up, using long overlapping strokes.  Applying from the bottom up helps 
avoid streaking. Allow to soak briefly. DO NOT allow detergent solution
to dry on the surface.  (Avoid working on hot surfaces or in direct sunlight 
to minimize the chances of the detergent drying, which may  result  in 
damaging painted surfaces.)  Be certain to rinse a small section at a 
time.
6. To rinse; lock the trigger gun in the "OFF" position, securely quick-connect
the desired high pressure nozzle into the end of the wand.  Unlock the 
trigger gun and spray.  It will take about 30 seconds to purge all detergent 
from the line.  For best rinsing results, start at the top and work down.
7.  Siphon a gallon of water through the low pressure detergent injection 
system  after  each  use.   This  prevents  the  possibility  of    corrosion  or 
detergent residue causing mechanical problems during the next use.
SHUT-DOWN:
.  DO NOT close the choke to stop the engine. Backfire or engine
damage  may  occur.  Turn  engine  "OFF"  as  directed  in  the  engine 
manual.
2.  Turn the water supply "OFF".
3.  Pointing the gun in a safe direction, trigger gun momentarily to relieve  
any trapped pressure.  
4.  Disconnect and drain the nozzle assembly, gun, wand and hoses.  
5.  Store complete assembly in a safe, non-freezing area.
 GP-SERIES Operator's Manual 
QUICK CONNECT DETERGENT
7

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido