Starting the Generator (Recoil Start-LPG]
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level .
3. Connect the regulator to both LPG cylinder and
generator.
NOTE: Do not place the LPG cylinder in the path of muffler outlet.
4. Fully open the LPG cylinder knob.
5. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned on.
6. Flip the engine switch to the "RUN"(l) position.
English
7. Flip the battery power restore switch to the " "
position for few seconds and then release.
8. Move choke lever located on engine to "START"
position.
9. PULL TO-PRIME:
-
Pull the starter cord 1-2 times. Pull slowly until
resistance if felt and then pull rapidly.
1-2 Times
10.Move the choke lever to the "RUN" position.
11. PULL TO RUN:
-
-
Pull the starter cord slowly until resistance if felt
and pull rapidly to run the unit.
If the engine fails to start in 1-2 pulls with choke in the
"RUN" position, then move choke lever to "START"
position and repeat the "PULL-TO-PRIME" step.
Page 19
Customer Service: 1-844-FIRMAN1
l