Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
Let the generator run at no-load for two
minutes to stabilize internal temperatures
of the engine and generator.
2. Flip the engine switch to the "OFF"(O) position.
3. Fully close the LPG cylinder knob.
If a cover is used, do not install until unit has cooled.
NOTE: Disconnect the LPG cylinder from the
generator during transportation.
WARNING
DO NOT stop engine by moving choke control
to "START" position.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
English
Indicator light - Battery Power Saving Mode
This generator is equipped with an electronic
module which consumes battery power. When
pull the starter cord or
restore switch , the indicator light will become
RED up to 4 minutes(before goes off).
Starting the engine successfully during these 4
minutes will turn the indicator light GREEN.
Starting the engine unsuccessfully or not attempting
to start the engine at all during these 4 minutes will
switch generator to Battery Power Saving Mode in
order to conserve and increase the life of battery.
MUST HAVE SOLID RED INDICATOR LIGHT TO
BE ABLE TO START THE GENERATOR. THE GENERATOR
CANNOT BE STARTED DURING BATTERY POWER
SAVING MODE UNLESS
PUSH THE BATTERY POWER RESTORE SWITCH.
Unwanted Shutdown:
The indicator light will start FLASHING for 4
minutes in the event of any unwanted shutdown
s u c h a s l o w o i l , r u n n i n g o u t o f f u e l
or any other unwanted shutdown. This is a reminder
that the generator is switching to Battery Power
Saving Mode. The generator should be checked.
For any unwanted shutdown:
If the generator cannot be started during or after
the 4 minutes of FLASHING mode, flip the engine
switch to "OFF" position and then restart by the steps.