Procom Heating MNSD2TPA Manual De Funcionamiento E Instalacion Del Propietario página 25

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Problem
When ignitor button is
pressed in, there is no
spark at ODS/pilot.
When ignitor button is
pressed in there is a
spark at ODS/pilot but
no ignition.
ODS/pilot lights but flame
goes out when control
knob is released.
200218-01A
All manuals and user guides at all-guides.com
TROUBLESHOOTING
Possible Cause
1. Ignitor electrode is posi-
tioned wrong. Ignitor elec-
trode is broken.
2. Ignitor electrode is not con-
nected to ignitor cable.
3. Ignitor cable is pinched or
wet.
4 Broken ignitor cable.
5. Bad piezo ignitor.
1. Gas supply is turned off or
equipment shutoff valve is
closed.
2. C o n t r o l k n o b n o t f u l l y
pressed in while pressing
ignitor button.
3. Air in gas lines when in-
stalled.
4. ODS / pilot is clogged.
5. Incorrect inlet gas pressure
or inlet regulator is damaged.
6. Control knob not in PILOT
position.
7. Depleted gas supply (pro-
pane).
1. Control knob is not fully
pressed in.
2. Control knob is not pressed
in long enough.
3. Equipment shutoff valve is
not fully open.
4. Thermocouple connection is
loose at control valve.
5. Pilot flame not touching
thermocouple, which allows
thermocouple to cool, caus-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged.
7. Control valve damaged.
www.usaprocom.com
Corrective Action
1. Replace pilot assembly.
2. Replace ignitor cable.
3. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry.
4. Replace ignitor cable.
5. Replace piezo ignitor.
1. Turn on gas supply or open
equipment shutoff valve.
2. Fully press in control knob
while pressing ignitor button.
3. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed.
4. Clean ODS/pilot (see Care
and Maintenance, page 23) or
replace ODS/pilot assembly.
5. Check inlet gas pressure or
replace inlet gas regulator.
6. Turn control knob to PILOT
position.
7. Contact local propane/LP
gas company.
1. Press in control knob fully.
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds.
3. Fully open equipment shutoff
valve.
4. Hand tighten until snug, and
then tighten 1/4 turn more.
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Care and Maintenance,
page 23) or replace ODS/
pilot assembly
6. Replace thermocouple
7. Replace control valve.
25

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Mnsd3tpaMnsd5tpaMnsd3tpa-bbMnsd5tpa-bb

Tabla de contenido