2) GENERAL INFORMATION
The SIRIO C MA 230 INV control panel comes with standard factory settings. Any
change must be made using the programmer with built-in display or universal
handheld programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
-
Control of 1 three-phase motor, with inverter
-
Electronic speed control with inverter
-
Obstacle detection
-
Separate inputs for safety devices
-
Configurable command inputs
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77. If the above-
mentioned terminals are being used, remove the relevant jumpers.
TESTING
The SIRIO CMA 230 INV panel checks (tests) the safety devices (photocells) before
performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Obstacle detection with encoder
Maximum motor power
Accessories power supply
AUX 3/ Output for audible signal
WIRING AND TERMINAL BOARD CONFIGURATION
Terminal
Definition
L
LINE
N
NEUTRAL
20
LIGHT 230V
21
26
AUX 3 - FREE CON-
TACT (N.O.)
(Max. 24V 0,5A)
27
41
+ REF SWE
42
SWC
43
SWO
50
24V-
51
24V+
52
24 Vsafe+
60
Common
61
IC 1
62
IC 2
63
Common
64
IC 3
65
IC 4
10 -
SIRIO CBA 230 INV
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
220-230V 50-60Hz(*)
> 2MOhm 500V
-10 / +50°C
Inverter
mains/LV 3750V~ for 1 minute
Present
750W
24V~ (demand max. 1A)
24V~safe
NO contact (24V~/max.0,5A)
Single-phase power supply 230V~ ±10%, 50-60Hz
Flashing light 230V output max. 40W
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN
ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK.
Refer to "AUX output configuration" table.
Limit switch common
Closing limit switch SWC (N.C.)
- Opening limit switch SWO (N.C.)
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Flashing light
Dimensions
Fuses
N° of combinations
Max.n° of transmitters that can be memorized 63
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
Install the electrical system referring to the standards in force for electrical systems
CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
5) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
6) DO NOT EDIT INVERTER SETTINGS. PROGRAMMING TO BE
CARRIED OUT VIA SIRIO CBA 230 INV CARD ONLy
Description
230V~ 40W max
146x170x60mm
see Fig. B
4 billion