Evolution 10-3x360-520/24
Art. No. 85001
OPERATING INSTRUCTIONS
EVOLUTION 3 PHASE 10
1
OUTPUT
24V / 10ADC - 28V / 8.3ADC
24V / 10ADC - 28V / 8.3ADC
2
Output OK / Alarm
Output OK / Alarm
Uout Adj. 22 - 28V
Uout Adj. 22 - 28V
3
Evolution 10
Art. No. 85001
Art. No. 85001
Murrelektronik GmbH
Falkenstraße 3
71570 Oppenweiler
GERMANY
IND.CONT.EQ.
IND.CONT.EQ.
DNVGL.COM/AF
E222272
E222272
IP20 SELV
IP20 SELV
Max. Surr. Air Temp.: +55°C
Max. Surr. Air Temp.: +55°C
Made in Czech Republic
Made in Czech Republic
!
Read instruc-
Read instruc-
tion
tion
manual
manual
before
before
use!
use!
INPUT Y (L-N) 208-300V
/
(L-L) 360-520V
, 0.80-0.50A, 50-60Hz
L1
L2 L3
4
93
93
93
132
7
3x400 VAC
PE
Art. Nr. 85001
Art. Nr. 85001
11
Art. Nr. 85001
Art. Nr. 85001
3x400 VAC
PE
Art. Nr. 85001
Art. Nr. 85001
12
Art. Nr. 85001
Art. Nr. 85001
L3
480-745 VDC
(-)
-
L2
(+)
+
L1
Art. Nr. 85001
Art. Nr. 85001
PE
13
(1) General
This unit employs many features previously unavailable in an industrial power supply. It has
been designed to withstand the high levels of interference found in heavy industry and has
emission levels low enough for it to be used in residential, commercial and light industrial
environments.
The Evolution 10-3x360-520/24 has a high level of reserve power. This enables loads with
significant inrush current to be supported and will also ensure that circuit breakers will trip in
event of short circuit.
A protective feature is provided which will take control as the unit approaches the power limit
due the overload or excessive temperature brought about by lack of ventilation.
If input voltage drops down to 3 x 300 VAC for 4 sec, output voltage still complies to PLC
standard EN 61131-2 (≥ 20,4 VDC).
Use only in star-architecture TN, TT and IT networks.
Only for use in pollution degree 2 environments.
In order to take the best advantage of the
features that this power supply has to offer
and to ensure long term reliability for your
equipment, please read these instructions
carefully before installation and use. They
should be retained for future reference.
5
6
5
28 VDC
66
24 VDC
66
2
2
4
6
8
Uin 3x400VAC /
Uout 24 VDC - 10 A
12
10
DC24V
8
6
4
2
0
DC48V
50%
100%
(DC +/ - 24V)
(DC +/ - 24V)
(2) Technical specification, Art. No. 85001
Nominal voltage (L-L)
Input voltage range (L-L)
Nominal voltage (L-N)
Input voltage range (L-N)
DC input operation nominal voltage
DC input operation voltage range
2-phase operation nominal voltage
2-phase operation voltage range
Nominal frequency
Input current, I
om.
Input current with two phase
Inrush current
Efficiency, typ.
Power factor, typ.
External fuse max. (*)
Safety class
Output voltage, adjustable 22 - 28 VDC
Static regulation accuracy
Dynamic regulation accuracy typ.
Start-up time
Hold up time of the output
Output current, continuous 24 VDC
Output current, continuous 28 VDC
Output current (power boost)
Output current, short circuit, typ.
Output ripple
Overloading / temperature protection
Overvoltage shutdown
Relative humidity
Operation temperature
Storage temperature
Protection class, case, EN 60529
Dimensions W x H x D; Weight
(*) For UL 508 use fuse Listed " UL 248 JDDZ Class CC rated 600V 10A".
8
(3) Features
[1] Output terminal:
Conductor sizes
Solid
Stranded
Stranded with ferrule without / with plastic sleeve
Stripping length
Wire insulation temperature rating 75°C.
Tightening torque: 0,5 Nm - 0,6 Nm / 4,4 lb. in. - 5,3 lb. in.
Screwdriver blade: 0,6 mm x 3,5 mm.
10
12
[2] Bi-colour LED, output voltage "OK" - green, Alarm - red.
[3] Output voltage adjust 22 - 28 VDC;
when over 24 VDC is used, must input voltage be accordingly higher.
9
[4] Input terminal:
Conductor sizes
Solid
Stranded
Stranded with ferrule without / with plastic sleeve
Stripping length
Wire insulation temperature rating 75°C.
Tightening torque: 0,5 Nm - 0,6 Nm / 4,4 lb. in. - 5,3 lb. in.
Screwdriver blade: 0,6 mm x 3,5 mm.
(4) Location
The power supply is cooled by natural convection. Top and bottom clearances should be
50 mm at minimum. Evolution three phase power supplies can be used side by side without
any distance. The ambient temperature should be measured on the underside of the unit.
10
There will be an increase of 25°C at the top. If natural convection is restricted, forced
cooling should be used. Mounting should comply with EN 60950-1 point 4.7 and 4.6.1.
Protection class of the case IP20 (EN 60529).
(5) Mounting [7]
The rail should be fixed solidly so that it cannot twist when mounting or removing the unit.
Mounting instructions [5], Removing instructions [6].
(6) Switching on
Factory set, ready to use, check the connection diagrams for parallel and series
connection. Check the connection diagram for DC use [13].
150%
(7) Loading capacity
The nominal current is 10 A but due to the nature of industrial loading, the power supply
has been designed to support loads with high inrush currents without damage or
shutdown. Curve [8] shows the typical voltage / current curve. Decreasing part of the
curve [8] shows the current limitation. Curve [9] shows the typical overload / temperature
limit. To ensure correct convection cooling, the unit must always be mounted with rail
horizontally. Power supply is designed to give 150% output power (power boost) for min.
4 seconds [10].
(8) Parallel connection [11]
Up to 5 units may be connected in parallel. The open circuit voltage of each unit should be
set to same value. Accuracy of setting will determine how well the units share the load
current. The gauge and lenght of the cable between each power supply and the common
point should be the same.
(9) Series connection
Up to 2 units may be connected in series to give either 48 VDC or +/-24 VDC. Check the
connection diagram [12].
(10) Using circuit breakers on the power supply output:
Using circuit breakers on the power supply output side up to 28 VDC we recommend
"MICO". For example: MICO 4.10, Art. No. 9000-41034-0401000.
More models on request or on our homepage: www.murrelektronik.com
For higher output voltages (series connection) and standard circuit breakers, power supply
will trip, for example the following ABB-STOTZ circuit breaker:
We reserve the right to change this specification.
3 x 360 - 520 VAC
3 x 324 - 572 VAC
3 x 208 - 300 VAC
3 x 187 - 330 VAC
2 x 380 - 520 VAC
2 x 340 - 572 VAC
0,8 A / 3 x 360 VAC - 0,5 A / 3 x 520 VAC
1,3 A / 2 x 360 VAC - 1,0 A / 2 x 520 VAC
< 15 A / 3 x 400 VAC after 1 ms
90% / 3 x 400 - 520 VAC
0,6 / 3 x 400 VAC and 24 VDC / 10 A
0->100%, 5% 1ms / 100%->5%, 5% 1ms
> 19 ms / 3 x 400 VAC and 24 VDC / 10 A
10 A (+55°C) / 6,5 A (+70°C)
8,3 A (+55°C) / 4,5 A (+70°C)
5 - 95% , no condensing
-25°C - +70°C (> +55°C derating)
93 x 132 x 114 mm; 1,3 kg
- S201-C2A
- S201-Z4A
V1.7
500 - 700 VDC
480 - 745 VDC
50 / 60 Hz ±6%
3 x 10 A (T)
1
24 VDC
+/-1%
< 400 ms
15 A / > 4 s
11 A
< 50 mV
ms
Yes
< 35 VDC
-40°C - +85°C
IP20
1,5 - 6 mm² / 16 - 10 AWG
1,5 - 4 mm² / 16 - 12 AWG
1,5 - 4 mm² / 16 - 12 AWG
8 mm
1,5 - 6 mm² / 16 - 10 AWG
1,5 - 4 mm² / 16 - 12 AWG
1,5 - 4 mm² / 16 - 12 AWG
8 mm