Dc Overload Protection; Ac Overload Protection - Westinghouse iGen1000s Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

#
Description
7.
AC ON/OFF button: The AC power
needs to be turned ON manually. Push
and hold to turn AC power ON/OFF.
The indicator light will illuminate when
main power is ON. Turn OFF when AC
power is not in use to conserve battery
life. Unplug all power cord from the AC
ports when not in use. If the AC power
is not used for more than 12 hours, the
unit will turn off automatically.
8.
Ventilation fans: The fans prevent the
unit from overheating. Never block or
obstruct the ventilation vents.
9.
6 AC outlets (120V / 60Hz): Used
to charge devices that require 120V
AC such as laptops, TVs, mini
refrigerators, vacuums, etc.
10.
Car outlet: Used to charge devices
that require a car outlet to be charged,
such as drone batteries. The Car
Outlet indicator light will illuminate
when the car outlet is in use.
11.
Solar / Car charging input port:
Supports a maximum of three 110W
solar panels to be connected in series.
Do not put more than two solar panels
in parallel connection. OnanS1000
has a limit input of 400W. Supports car
charge with a maximum input of 8A.
12.
AC charging input: Plug in the
supplied AC cord into the port and
connect the three-pin plug into a
120V/60Hz AC power source.
13.
Overload protection switch, 20A: If
the input current exceeds 20A during
charging, the AC charging port will
trigger the overload protection (See
Notification Icons section). When the
overload indicator has turned off, push
the Overload Protection button to reset
and continue charging.
8 | Westinghouse Outdoor Power Equipment, LLC

DC OVERLOAD PROTECTION

When any DC port is powering devices that
exceed maximum current limit, or the output
power of the AC jack exceeds the maximum
AC power output, the overload icon will be
shown on the display and the corresponding
interface indicator will flash simultaneously for
15 seconds. The output of the affected port
will be automatically turned off. Other ports will
continue to operate.
Remove the devices connected to the DC ports.
Make sure the Power Station can supply enough
continuous (running) and peak (starting) watts
for the items you will power at the same time
before reconnecting devices.

AC OVERLOAD PROTECTION

When the power output exceeds the battery
maximum power output, the overload icon will
be shown on the display and the corresponding
port indicator will flash simultaneously for 15
seconds. The unit will automatically shut down.
After an overload occurs, remove the connected
devices. Make sure the Power Station can
supply enough continuous (running) and peak
(starting) watts for the items you will power at
the same time before reconnecting devices.

Publicidad

Tabla de contenido
loading

Tabla de contenido