INSTALLATION
Before installation, first check that the device has not been damaged during transportation.
Battery connection:
- Remove the covers of the external battery terminals
- Connect the battery to the polarity: the red cable at the battery terminal (+); the black cable to
the battery terminal (-)
NOTE: For user safety please use insulating tape on the battery connections before using the
device
INSTRUCTIONS FOR USE
ATENTION:IT IS MANDATORY THAT YOU TURN ON DEVICE AFTER PROCEDURE:
Turn on device: after you have plugged the power plug of the UPS into a 230V outlet, press and hold the power button to
turn on the device.
Turn off device: long press the shut down button to turn off the device.
The front panel contains an LCD screen and several LEDs that show how the device works.
SETTINGS
Press the "ENTER" button for 2 seconds to enter the device setting mode. Press the "ENTER" button again to select the
desired setting option. Press the "SEL" button to change a parameter. Long press the "ESC" button to exit the setting mode.
All changes will take effect after the device restarts.
Option
Option
Description
04
Frequency signal
13
Bulk current
Absorption charge
17
voltage

Led indicators

Messages
Backup mode
Line mode
Charger mode
All LEDs are off.
Low battery voltage
Buzzing every 2 seconds and red LED
warning
blinking
Buzzing every 2 seconds and red LED
Overload warning
blinking
Fault mode
Buzzing continuously and red LED is on
Values
50 Hz (default) / 60 Hz
10 ~ 30A (default value 10A)
13.8 ~ 14.5 V (default value 14.1 V)
5
EN
Value