Float charge voltage
19
Shutdown voltage
24
Alarme
25
Enable key tones
29
Grid charge enable
To reset all parameters to the default factory settings, press and hold the "SEL" button, select the "DEF" option then press the
"SEL" button again to confirm. Restart the device and the parameters will be reset.

OPERATING MODE DESCRIPTION

Operation mode

Fault mode
Charger mode
Line mode
Battery mode
FAULT REFERENCE CODE
02
03
04
05
06
07
11
Description
If an error occurs in the device's
operating mode, it will automatically go
into error and its code will be displayed
on the screen
In this way the external battery will be
charged
In this way the output will feed directly
from the input and will charge the
battery at the same time.
If the input voltage has a value other
than
the
~ 240V), the AVR function will be
activated
input behaves abnormally, the device
automatically switches to battery mode.
In this way the output will take off the
battery.
Over temperature
Battery voltage is too high
Battery voltage is too low
Output short circuited
Inverter output voltage is high
Overload
Main relay fault
13.5 ~ 13.7 V (default value 13.5 V)
10.0 ~ 12.0 V (default value 10.5 V)
= enabled (default)
= disabled
= enabled (default)
= disabled
= enabled (default)
= disabled
acceptable
range
(200
automatically.
When
the
Input voltage too low
41
Input voltage too high
42
Input frequency too low
43
Input frequency too high
44
AVR fault
45
Over current
51
Inverter output voltage is low
58
6
Display