DESCRIPTION
DESCRIPTION OF THE TEKNA S PLUS MONITOR
Monitor for the Plus system with button and coded panels.
k
a
l
b
m
c
n
g
o
p
h
d
q
i
k
j
a.
Handset.
b.
4.3" TFT colour screen.
c.
Communication with hearing aids.
e
Set the hearing aid switch to position T.
d.
Function/programming buttons.
e.
Telephone cord.
f
f.
Cord connector.
g.
Brightness control.
DESCRIPTION OF THE CONNECTION TERMINALS
CN3 connection terminals:
_
Vin
V out
( )
+
*
MP
VP
Malla
, +
:
Negative,
positiv
e (18Vdc power supply)
–
Vin:
Video signal input through coaxial cable
( )
–
:
Coaxial cable shield.
*
Vout:
Video signal output through coaxial cable
Vp, Mp:
Balanced video signal (through twisted
pair).
FUNCTION BUTTONS
With the monitor in standby and the handset on the hook: One long 2-second press activates 'ringtone volume'
mode, with a tone indicating the current volume selected. Then each long 2-second press (before 5 seconds
elapse) selects a volume level: maximum, no volume 'night mode,' minimum and medium, and so on (carousel
mode). Note: The 'night mode' status LED blinks red.
With the monitor in standby (handset on or off the hook), call or communication: One long 3-second press turns off
the monitor. Then one short 1-second press turns on the monitor.
( )
With the handset off the hook: This activates the intercom (in the same apartment); one long press until a confirmation
*
tone can be heard will call all of the monitors in the apartment. To call individual devices, press the button once to
call the 'master' monitor, twice to call 'slave 1' and so on up to 5 presses to call 'slave 4.' This only functions if no call
or communication is in progress. Note: With Tekna Plus monitors (see the TTekna S Plus manual).
( )
This activates auxiliary device 'A1' with the monitor in standby (handset on or off the hook), call, communication or
*
intercom.
With the monitor in standby and the handset on the hook: This enables the image from the door panel configured as
main to be viewed (if the bus is busy, the status LED of the monitor will indicate so with a few quick blinks).
With the monitor in standby and the handset off the hook: It enables audio and video communication with the door panel
to be established if it has its auto switch-on function activated. This only functions if no communication is in progress.
In call: A slave monitor enables the image of the door panel to be captured.
With the monitor in standby and the handset on the hook: This makes a panic call to the guard units configured to
receive such calls.
With the monitor in standby and the handset off the hook: It enables a normal call to the main unit to be made.
During call reception and communication processes, it enables the lock release to be activated.
( )
In advanced programming mode, the default functions of function buttons
*
TTekna S Plus manual).
h.
Colour control.
i.
Advanced programming LED.
j.
Monitor status LED (two-colour):
-
In standby: LED illuminated red.
-
Call: LED illuminated green
(master monitor).
-
Communication: Green LED ON.
-
Auto spy if Bus busy:
CN4
75
SW1
Ω
LED blinking red rapidly.
1 2 3 4 5 6 7 8 9 10
-
No volume (night mode):
CN2
JP1
LED blinking red.
CN3
-
Doctor mode: LED blinking
green.
k.
Connector fixings.
l.
CN4 connector (end of line jumper).
m.
JP1 jumper, remove in video
installation with twisted pair (see
TTekna S Plus manual, code
50122251).
n.
RJ-45 connector (installation with
UTP cable).
o.
SW1 configuration switches.
p.
CN2 connection terminals.
q.
CN3 connection terminals.
CN2 connection terminals:
_
_
-
A
D
INT
2C A1
HZ
AP+
A:
.
Audio communication.
D:
Digital communication.
HZ-:
Door bell button input.
AP+:
Input for auxiliary door opening button.
.
INT:
Intercom function.
2C
Output for 2nd camera activation.
A1:
Output (negative) for aux device activation (max.
.
SA:
Output (negative) for aux call repeater (max.
.
and
can be changed (see the
2
OPERATION
-
Call reception: During call reception, the image will appear on the monitor(s) and the status LED on the master monitor
will illuminate (green). If the call is not answered within 45 seconds, the master monitor's status LED will illuminate
(red), LED on the door panel will turn off and the channel will become free.
-
To establish communication, lift the handset of the monitor, and the monitor's status LED (green) and the door panel's
LED will illuminate. Communication with hearing aids
hearing aids equipped with T-mode. Note: Set the hearing aid switch to the T position, making conversation possible
(inductive loop).
-
The communication will last for one and a half minutes or until the handset is replaced. After communication, the
monitor's status LED will illuminate (red), the door panel's LED will turn off and the channel will be free.
-
To open the door, press door release button
the lock release for 3 seconds and LED will also illuminate for 3 seconds.
INSTALATION OF THE TERMINAL
Avoid dusty or smoky environments or locations near sources of heat. The monitor can be fixed to an electrical
embedding box or directly to the wall.
Location
1.60m
+ SA
Remember to remove the protective covering from the front of the monitor once installation is complete.
WIRING DIAGRAM
Tekna S Plus
I.
50mA).
I.
250mA).
Tekna S Plus
M =
Master
.
*Place this power supply as
close as possible to the
first monitor.
FA-Plus/C
or
FA-Plus
PRI
SEC
~
~
+ +
-
-
Mains
I
MPORTANT
:
For further information about the door panel, sections, distances, wiring diagrams, etc., see the T632 Plus P/T manual.
EN
https://doc.golmar.es/search/manual/ 50122328
: The handset of the monitor enables communication with
during the call or communication processes: one press will activate
I
mportant:
For further information, see TTekna S Plus manual (code
Surface
4 30
x
D4L-PLUS
Tekna S Plus
M
M
(1)
CN4
CN4
S
JP1
_
_
+
V
V
A
D
+
V
V
A
D
D1
E
D2
in
out
in
out
+
D4L-PLUS
Tekna S Plus
M
M
JP1
CN4
CN4
S
_
_
+
V
V
+
V
V
A
D
D1
E
D2
A
D
in
out
in
out
+
3
50122251).
Embedding box
Screws supplied with
he embedding box.
(1)
Remove the JP1 jumper
from all of the distributors
except the last
Access panel
CN3
M
10
9
8
7
6
1
2
3
4
5
SW2
SW1
CN1
CV2
CV1
- +
+
-
D
A
A
V
V
V
V
Malla
out
in
in-
in+
out+
out-
DC lock
release
EN