What is Included
•
onAir IP Panel 2
•
Seetronic Powerkon IP65 cable
•
Omega bracket with mounting hardware
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 V~, 50/60 Hz.
Power Linking
You can link up to 3 onAir IP Panel 2 products at 100 V, 4 products at 120 V, 7 products at 208 V, 8 products at
230 V, or 8 products at 240 V. Never exceed this number. Power linking cords can be purchased separately.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
DC Power
This product has a 3-pin IP65 XLR power input port that can work with an input voltage of 28 V DC.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
Signal Connections
The onAir IP Panel 2 will work with a controller or controller software using a wired DMX connection, a wireless
Lumenradio CRMX™ connection, or an Ethernet connection, If using other Art-Net™ or sACN-compatible products with
the onAir IP Panel 2, each can be controlled individually on a single network. See the User Manual for information about
how to connect and configure the product for these signals.
Control Personalities
uses
The onAir IP Panel 2
6Ch
8Ch
11Ch
15Ch
,
,
,
DMX Connection
The onAir IP Panel 2 will work with a DMX controller using a 5-pin DMX data connection or a wireless CRMX™
connection. A DMX Primer is available from www.chauvetprofessional.com.
Art-Net™ Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller's User Manual or with the manufacturer as not all DMX controllers
have this capability. The onAir IP Panel 2 supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from
Wireless Operation
In optimal conditions, the onAir IP Panel 2 can operate up to 300 m (900 ft) away from the CRMX™ transmitter, The
CRMX™ receiver in the onAir IP Panel 2 must be paired with the CRMX™ transmitter for wireless operation.
Initial Setup
1. Turn the CRMX™ transmitter on.
2. Connect the CRMX™ transmitter to a DMX controller.
3. Place the onAir IP Panel 2 within 300 m from the CRMX™ transmitter.
4. Turn the onAir IP Panel 2 on.
Configuration
1. From the onAir IP Panel 2's control panel, go to DMX Address.
2. Select the start address, as with any other DMX compatible product.
3. Go to Wireless Setting > Receive On/Off.
4. Select On. (The Signal Strength Indicator will show a ? in front of the bars)
5. Press the reset button on the CRMX™ transmitter. (The Signal Strength Indicator on the onAir IP Panel 2 will
show a ϟ in front of the bars for 3 seconds while a connection is established.)
onAir IP Panel 2 QRG Rev. 3
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
DMX, CRMX™, Art-Net™, and sACN for its control personalities:
16Ch
18Ch
23Ch
,
,
,
, and
www.chauvetprofessional.com
•
Junior pin
•
Quick Reference Guide
Wire (Europe)
Brown
Blue
Green/Yellow
32Ch
.
for more details.
EN
Screw Color
Yellow/Brass
Silver
Green
1Ch
3Ch
4Ch
5Ch
,
,
,
,
2