SICK WTB16 Manual Del Usuario página 29

Ocultar thumbs Ver también para WTB16:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
8020346.1DS6/2021-11-24 | SICK
Subject to change without notice
1
2
3
Figure 21: WTB16x-xxxxxx1xAxx, adjusting the sensing range with potentiometer
WTB16x-xxxxxx3xAxx with teach-in button:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.). We
recommend placing the object within the sensing range, see figure 10 for an example.
Once the sensing range has been adjusted, the object is removed from the path of
the beam, which causes the background to be suppressed and the switching output to
change
(see table
4).
1
1...3 sec.
2
Figure 22: WTB16x-xxxxxx3xAxx, adjusting the sensing range with teach-in button
COMMISSIONING
O P E R A T I N G I N S T R U C T I O N S | WTB16
7
en
29

Publicidad

Tabla de contenido
loading

Tabla de contenido