4

MOUNTING

4
Mounting
en
5

Electrical installation

22
O P E R A T I N G I N S T R U C T I O N S | WTB16
WTB16x-xxxxxx30
1
2
4
3
BluePilot blue: sensing range display
1
Press-turn element / Potentiometer / Teach-Button: adjusting the sensing range
2
LED yellow: status of received light beam
3
LED green: supply voltage active
4
Press-turn element: time function adjustment
5
Teach pushbutton: adjustment of light/dark switching
6
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
Note the preferred direction of the object relative to the sensor,
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Note pin assignment.
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations on connection diagram:
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 7: Connections
Wxx16x-
x4
1 = BN
2
2 = WH
3 = BU
4 = BK
3
5= GY
WTB16x-xxxxxx31
6
1
2
4
3
xH
1
2
0.14 mm
2
AWG26
4
3
WTB16x-xxxxxx32
5
1
2
4
3
see figure
23,
figure
24.
x5
xI
1
5
4
0.14 mm
2
AWG26
8020346.1DS6/2021-11-24 | SICK
Subject to change without notice