Connection to the mains (service technician)
The device may be connected to the power supply
only by the authorized and qualified personnel,
when the valid regulations are followed and when
appropriate material is used in accordance to the
regulations.
Depending on the model the devices are designed
for connection to the following networks:
400 V 3N~ 50-60 Hz
During the installation follow the data on the rating
plate.
Before connecting the device to
the mains, check whether the device is
connected to the appropriate circuit
breaker in all poles with minimum air
gap of 3 mm.
GB
To correctly connect the device, follow the
guidelines below.
Remove the cover from the terminal strip (A).
A
Connect the switch-off to the terminal strip (B)
of the device, as shown in the drawing and
block diagram (see the attachments). Use
cable type H07RN-F or better, min. heat
resistance of 80 °C.
Firmly press the end of the cable (C).
Replace the terminal strip cover.