CONTENTS
1
GENERAL PRESCRIPTIONS
1.1
Safety prescriptions
1.2
Installation prescriptions
1.3
Operating prescriptions
2
MODELS AND PRODUCTS DESCRIPTION
2.1
Description
2.2
Typical installation
3
PRODUCT TECHNICAL SPECIFICATIONS
4
INSTALLATION
4.1
Preliminary checks
4.2
Operating limits
4.3
Preparatory work for installation
4.4
Installing the M operator
4.4.1 Installation
4.4.2 Installation of limit stops and switches
4.4.3 Operator manual release
5
PREPARATION FOR ELECTRICAL CONNECTIONS
6
TESTING
7
PRODUCT MAINTENANCE
8
SPARE PARTS
9
DISPOSAL OF THE PRODUCT
10
WARRANTY
1 PRESCRIPTIONS
1.1 SAFETY PRESCRIPTIONS
This installation manual is addressed exclusively
to professionally skilled personnel. Read all the
instructions carefully before starting the installation
procedures. Any operations that are not expressly
set down in these instructions are to be considered
prohibited; improper use may result in damage to
the product and place persons and property at
risk.
The manufacturer declines all liability for failure
to observe best practices in gate construction
and for any possible deformation that may occur
during use of the product. Store this manual in a
safe place for future reference. The design and
construction of the devices of which model M is
composed and this manual are in full compliance
with statutory legislation.
In consideration of potential hazards that may arise
during the installation and use of M220, M300,
M500, the installation procedures must be carried
out in full compliance with the applicable laws,
standards and regulations; namely:
1.2 INSTALLATION PRESCRIPTIONS
• Before starting the installation procedures
make sure you have any additional devices
and materials that may be required to complete
the M220, M300, M500 gate opener in
consideration of the specific application.
• The gate opener must not be used until the
system has been commissioned as specified
in heading:
• Dispose of packaging materials in compliance
with local regulations.
All manuals and user guides at all-guides.com
1.3 OPERATING PRESCRIPTIONS
• No modifications can be made to any part of
• The parts of the automation system must never
• If liquids penetrate any parts of the automation
• Keep all parts of the M220, M300, M500 gate
• When the equipment remains unused for a long
• Connect the control unit exclusively to an
• Any operations that require the housing of
• In the case of tripping of circuit breakers or
• If the fault cannot be remedied using the
2 PRODUCT DESCRIPTION AND INTENDED
USE
2.1 PRODUCT DESCRIPTION
Reversible electromechanical operator with telescopic rod for residential
gates. The rugged die cast aluminium structure can accommodate brush
motors or single phase motors, so the operator can be supplied in either a
24V version or a 110V version. Aluminium housing with weather resistant
powder coating.
the product unless specified in this manual.
Unauthorized modification of the product is
likely to lead to malfunctions. The manufacturer
declines all liability for damage caused by
unauthorized modifications.
be immersed in water or other liquids. During
the installation procedures ensure that no liquids
penetrate inside the control unit or other open
devices.
system disconnect the electrical power supply
immediately and consult Comunello technical
service; the use of M220, M300, M500 in such
conditions may give rise to potentially hazardous
situations.
opener away from heat sources and open
flames; exposure to heat or flames may damage
the devices and cause faults, fire, or hazardous
situations.
time, remove the optional battery and store it
in a dry place to avoid the risk of leakage of
harmful substances.
electrical power supply line equipped with an
efficient protective earth conductor.
M220, M300, M500 to be opened must be
performed with the control unit and the electrical
power supply disconnected; if the disconnect
device is not clearly visible from where you are
working, attach a warning notice to the effect:
"WARNING - MAINTENANCE IN PROGRESS".
blowing of fuses, find the fault and remedy it
before resetting the circuit breaker or changing
the fuse.
information given in this manual, consult
technical service.
MERIK ®Copyright 2015 - All rights reserved
11