Care And Maintenance; Troubleshooting - Portfolio E3A Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Connect bare ground wire from the base (D) to the ground
wire coming from the concrete by twisting a wire nut (EE)
onto bare ends of the wires. Connect white wire from the
base (D) to the white wire coming from the concrete by
twisting a wire nut (EE) onto bare ends of the wires. Connect
the black wire from the base (D) to the black wire coming
from the concrete by twisting a wire nut (EE) onto the bare
ends of the wires. Secure the wire nuts (EE) with electrical
tape (not included).
Hardware Used
Cap nut
CC
Washer
DD
Wire Nut
EE
 
7. CAUTION: Allow the concrete to dry before installing the
pole assembly.
With the help of another person, align the holes on base (D)
with the anchor bolts (BB) and carefully place the pole
assembly over the mounting bracket (AA). Secure assembly
with washers (DD) and cap nuts (CC), tightening with a 1/2
in. wrench (not included).

CARE AND MAINTENANCE

To clean, unplug lamp and wipe with a damp, non-abrasive cloth.
 
 

TROUBLESHOOTING

PROBLEM
The fixture shakes in high
winds.
x 3
x 3
x 3
POSSIBLE CAUSE
1. The mounting bracket may be
assembled incorrectly.
2. The screws and cap nuts may
be secured incorrectly.
 
CORRECTIVE ACTION
1. Make sure the mounting
2. Make sure the screws and
6
 
6
bracket was installed at
ground level.
cap nuts were secured tightly.
EE