Descargar Imprimir esta página

cleanAIR 50 01 66 Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
1. Instructions
• Make sure that all filters used are new and intact.
• If the air purifying unit is fitted with more than one filter, all filters used at the same time must be the same type (a set
of two / three identical filters).
Filters can only be used if the following rules are, or have been, observed:
• The user must be aware of the nature of contamination and the level of concentration in the ambient air.
• Oxygen concentration in the ambient air in the premises where the unit is used must not drop below 17 percent.
• The air purifying unit must not be used in confined spaces, e.g. enclosed containers, tunnels, channels, etc.
• Warning: high concentration of vapours that are heavier than air can occur at low height above the ground.
• If any of the conditions mentioned herein is not met, a self-contained oxygen breathing apparatus must be used (i.e.
one with an oxygen bottle).
• Filters the purpose of which is to filter out solid and liquid particles do not protect users from the exposure to gases.
• Gas filters do not provide any protection against particles.
• In case of contamination of working environment by both gas and particles it is necessary to use the combined filters.
• Special regulations must be observed in case of contamination by gases that are hard to identify.
• Filters need to be replaced whenever you feel any change in the odour of the air supplied by the unit.
• Only certified and original filters that are intended for use in your CleanAIR filtration unit can be used.
• Expired filters must not be used. The expiry date is indicated on each filter.
• Be careful when working in an environment where open flame or flying hot particles are present. The filter may catch
fire and the wearer's life can be in danger!
• Filters that filter out mercury (Hg) must not be used for more than 50 hours!
WARNING!
In case of any breach of proper filter use principles the warranty shall cease to exist!
2. Canister type filters – 50 00 ..; 50 01 ..; 50 02 ..; 50 03 .., 56 00 ...
Standard canister type filters with the RD 40x1/7" thread pursuant to standard EN 148-1 are suitable for use along with
the air purifying units CleanAIR
same type.
Canister type filter replacement:
Remove the filter by unscrewing counter-clockwise. WARNING! Before you install new filters, make sure they are new
and intact and in their original packaging and that their usable-life period has not expired (as indicated on the body of
each filter). You must also make sure the gasket in the connection between the filters and the unit is intact. It is necessary
to make sure the unit is fully fastened, so as to provide tightness. If a pre-filter is used (50 01 10), affix it to the body of
the filter using a plastic holder (50 01 09) that is simply pushed onto the upper part.
In case of any doubts regarding the nature of work environment contamination, it is recommended that combined filters
be used. Before filter replacement, familiarize yourself with the operating instructions for the piece of equipment or
headpiece onto which the filter is installed.
Special rules must be observed when using combined filters the purpose of which is to filter out hazardous
radioactive particles.
For filter replacement demonstration, see figures 1A – 1C, filter for the CA Asbest 4A - 4B
3. Combined filter for the CA Pressure Conditioner unit
This powered air purifying station contains a combined filter (61 00 10) against dust, solid particles and aerosols. The
filter removes toxic solids and gases from industrial compressed air.
Read the operating instructions before use and filter replacement.
Up to two employees using the CleanAIR Pressure units can be connected to one filter station.
Filter replacement:
Unscrew the upper part of the filter station (6 screws).
Remove the contaminated filter and wipe out the inside of the container.
Inspect the condition of the rubber gasket in the cap. If it is damaged, install a new one.
Install the new filter onto the container cap and reinstall the upper part.
Inspect the container, making sure it is airtight.
For filter replacement demonstration, see figures 2A – 2C
®
Chemical, Chemical 3F or 2F. All filters used in the unit at the same time must be of the
EN

Publicidad

loading

Productos relacionados para cleanAIR 50 01 66