rotated in the socket so that the contacts on both sides are in the plane of the fi xing slot (VI). Then remove the fl uorescent lamp
and install a new one by sliding it into the socket and turning it.
Caution! The surface of the fl uorescent lamp should not be touched with bare fi ngers. The replacement must be done in gloves.
The used fl uorescent lamp should be handed over to an electrical waste treatment plant in accordance with local regulations.
Remote control
The remote control has buttons which are described and operate in the same manner as the control panel buttons. Batteries must
be installed in the remote control for proper operation, paying attention to the correct polarity of the batteries.
Control panel
The control panel allows you to control the operation of the appliance. The panel is equipped with touch buttons and indicator
lights informing about the appliance settings.
The "ON/OFF" button is used to turn the appliance on and off . When the appliance is switched off , only the switch is illuminated.
When the appliance is on, all buttons and selected indicator lights are illuminated.
The "Air speed" button is used to set the fan speed. Higher speed increases operation capacity, but also causes more noise.
The "Timer" button is used to set the operating time. The next press of a button increases the operation time which is presented
on the display. Flashing button illumination indicates that the timer is set, which will switch off the appliance after the pre-set time.
The button's constant illumination indicates uninterrupted operation.
The "Automation" button - starts and stops the automatic mode where the appliance automatically selects the operating parame-
ters. The activation of this mode is indicated by fl ashing button illumination.
The "Sleep mode" button - starts and stops the night mode, where the appliance switches off the control panel in addition to illumi-
nating the "Sleep mode" button. This mode should be set for the night when the appliance is to operate in the same room where
people are sleeping. Pressing the button will cause its illumination to fl ash, and after a few seconds the appliance will automatically
turn the control panel illumination off and leave only this button illuminated. You can exit the night mode by pressing any button
and then pressing the "Sleep mode" button again to stop the illumination from fl ashing. The fl ashing of the "Sleep mode" button
illumination means that the appliance will automatically switch to night mode after a few seconds.
The "Anion" button starts or stops the air ioniser. When the ioniser is activated, oxygen anions are produced in the appliance,
which can have a positive eff ect on your well-being. When the air ionisation is activated, the button illumination will fl ash.
The "Germicidal lamp" button activates or deactivates the UV emitting fl uorescent lamp. When the fl uorescent lamp is activated,
the button illumination will fl ash.
The "Child lock" button activates the control panel lock, which does not allow any of the buttons to be pressed. The lock is deac-
tivated by touching and holding this button for a few seconds.
The "Replace fi lter" button - fl ashing of this button's illumination means that the fi lters must be replaced. After replacing the fi lters,
press the button to stop the illumination from fl ashing.
The "Child lock" indicator light - informs about the lock status of the control panel. If the open padlock symbol is illuminated this
means that the lock is not active, and when the closed padlock symbol is illuminated this means the control panel is locked.
The "Temperature" indicator light shows the air temperature in the room where the appliance operates.
The "Humidity" indicator light shows the relative humidity of the room where the appliance operates.
The "Intelligent air purifi er" indicator light shows the amount of PM2.5 particles in the air in μg/m
and also shows the air quality
3
using the illumination colour. Green - good quality, orange - medium quality, red - bad quality. The air quality is also indicated by
the illumination colour of the lamp at the front of the appliance.
An indicator light with a fan symbol shows the current fan speed.
MAINTENANCE, TRANSPORT AND STORAGE
Warning! All maintenance works and transport must be carried out with the appliance's electric power supply disconnected. Pull
the plug out of the power supply socket.
Clean the appliance from outside with a slightly damp cloth and then wipe dry with a dry cloth. Clean the inlet and outlet vents
with a paintbrush or soft bristle brush. The fi lters do not require cleaning, dirty fi lters should be replaced with new ones. The fi lters
cannot be regenerated or cleaned.
If the water tank is installed in the appliance, it must be emptied. In addition to the removable tank, there is a fi xed tank in the
appliance, which must be emptied by pulling water from it using a pump (not included). Water should be removed from the tanks
not less frequently than every three days. Do not keep the water in the tank due to the possibility of growth of microorganisms.
Before refi lling, clean the tank with clean water. Remove any scale, sediments or fi lm which has accumulated on the walls or inside
the tank. Then wipe the tank dry. Pour one tablespoonful of citric acid into the tank and 100 ml of warm water with the temperature
not exceeding 70
O
C. Mix the acid and leave the solution in the tank for 5 minutes. Then empty the tank, rinse with clean water
and leave it open until completely dry.
Never use solvents, acids, or alcohol for cleaning. Clean the base and the lid with a soft, damp cloth. Never immerse the appliance
in water or any other liquid.
Transport the appliance by gripping the handles. Transport in operating position. If transported over longer distances, transport