Switching On And Off; Sealing; Cleaning And Maintenance; Cleaning - Deltafox DP-CCG 1830 Traducción Del Manual De Instrucciones Origina

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 106
GB
Level 5 – nozzle opening min. 9 mm
Level 6 – nozzle opening min. 9.5 mm
Make sure that the opening of the
cartridge nozzle is large enough.
If the cartridge nozzle is too small
and the feed rate is too high, there
is a risk of sealant/glue being
pushed through the bottom of the
cartridge, contaminating your de-
vice.
Slowly turn the controller when the
device is in operation.
1. Turn the controller (8) anti-clockwise
to the desired feed rate.

Switching on and off

To begin working, switch the con-
troller (8) to level 1.
Switching on
1. Press the on/off switch (7).
The push rod (3) automatically moves
forward.
The LED work light (6) turns on and illumi-
nates your work area.
Switching off
1. Release the on/off switch (7).
The push rod (3) automatically moves
back a bit, taking the pressure off the car-
tridge and preventing the material to be
dispensed from dripping.
26

Sealing

Press the on/off switch (7) and apply the
sealant/glue evenly at the designated
spot. Hold one hand under the cartridge
holder (1) to support the device while you
are working.
The cartridge holder (
elled 360° and allows you to point the cut
nozzle tip to the designated spot.
After working, wipe the sealant/glue off of
the tool before it dries.
If the cartridge is empty, the push rod (3)
will automatically move back a bit.
Cleaning and
maintenance
Switch off the device and remove
the battery before carrying out
any maintenance work.
You should have any repair and
maintenance work that is not
described in these instructions
carried out by our Service Centre.
Only use original parts.
The following cleaning and servicing
should be done regularly. This will ensure
a long and reliable service life.

Cleaning

The device must not be sprayed
with water or placed in water.
Otherwise there is a risk of elec-
tric shock.
Do not use any cleaning agents
or solvents. This could damage
the device irreparably. Chemical
substances may attack the plastic
parts of the device.
1) can be swiv-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dp-ccg 1830 set

Tabla de contenido