One vacuum pad is supplied with the Vac-U-Rig
separately for other Dymorigs. The vacuum pad is most effective when it
is secured to a relatively smooth surface such as poured concrete. If the
surface is too porous or rough, the pad may not hold securely. Before us-
ing a vacuum pad, always check the gasket on the underside of the pad
to make sure it isn't worn, cracked or torn. If it is, immediately replace the
gasket, otherwise the vacuum pad may not hold the rig securely. To replace
the gasket, see "Replacing Vacuum Pad Gaskets" in the "Maintenance"
section. See "Accessories" for gasket part number.
1.
To use the vacuum pad, tilt the base of the rig and slide the vacuum
pad under it so the threaded stud goes through the hole on the end of
the center slot on the base. Then set the stand upright.
2.
Position the rig as required for coring the hole.
3.
Level the rig with the four (4) leveling screws using the bubble level
(4125 & 4130 only) as a guide. When the rig is level, tighten the four
(4) nuts (4125 & 4130 only) on the leveling screws.
4.
Connect one end of the supplied vacuum hose to the vacuum line
coupler on the vacuum pad. To do this, pull back the collar on the hose
and push the end of the hose onto the coupler until in snaps into place.
Then, connect the other end of the vacuum hose to the coupler on the
vacuum pump following the same procedure.
5.
The vacuum pump may be set on a dry surface away from the rig or
mounted to the base of the Dymorig as shown. However, DO NOT
mount the vacuum pump to the Dymorig when angle coring.
To mount the vacuum pump on the Dymorig, place the small hole on
the vacuum pump mounting bracket over the vacuum pad stud on the
Dymorig.
6.
Plug the vacuum pump into the power source—the pump will start
automatically. Step on the vacuum pad or the vacuum pad stud until
the vacuum pad lowers and adheres to the work surface.
7.
After the pad is secured to at least 20 inches of mercury vacuum, tighten
the vacuum pad nut securely.
The vacuum gauge must read a minimum of 20 inches
of mercury vacuum. To reduce the risk of injury DO
NOT CORE if the gauge reads less than 20 inches of
mercury vacuum.
Using an Expansion-Type Anchor (Fig. 13)
Fig. 13
Leveling
Screws
For Cat. No. 4115 & 4120 only.
Use a 5/8" expansion-type anchor (not supplied) that will accept a 5/8"
threaded rod or bolt to secure the base to the work surface.
1.
Remove the rubber gasket from the base.
2.
Level the rig with the four (4) leveling screws.
3.
Using an expansion-type anchor, insert a threaded rod or bolt through
the slot located in the base of the Dymorig and tighten the bolt or washer
and nut fi rmly in the anchor following the manufacturer's instructions.
page 8
®
and they can be purchased
WARNING!
Rod or Bolt
Assembling and Using a Vacuum System (Fig. 14 & 15)
Fig. 14
Vacuum Release
Valve
Small Hole
for Attaching
Pump to Dym-
orig Stand
Vacuum Hose
Fig. 15
Vacuum
Pad
Gasket
Vacuum Adapter Assembly
For Cat. No. 4120 only.
The vacuum pad is most effective when it is secured to a relatively smooth
surface such as poured concrete.
If the surface is too porous or rough, the vacuum pad may not hold securely.
Before using the vacuum pad, always check the gasket on the underside
of the base to make sure it isn't worn, cracked or torn. If it is, immediately
replace the gasket, otherwise the vacuum may not hold the rig securely.
To replace the gasket, see "Replacing Vacuum Pad Gaskets" in the "Main-
tenance" section. See "Accessories" for gasket part number.
1.
Position the rig as required for coring the hole.
2.
Loosen the four (4) leveling screws until the ends are above the bottom
surface of the base.
3.
Place the vacuum adapter assembly into the slot in the base.
4.
Connect one end of the supplied vacuum hose to the vacuum line
coupler on the vacuum base. To do this, pull back the collar on the
hose and push the end of the hose onto the coupler until it snaps into
place. Connect the other end of the vacuum hose to the coupler on the
vacuum pump following the same procedure.
5.
The vacuum pump may be set on a dry surface away from the rig or
mounted to the base of the Dymorig as shown. To mount the vacuum
pump on the base, place the small holes on the vacuum pump mount-
ing bracket over the two tapped holes on the base. Attach the vacuum
pump to the base with two (2) 1/4" - 20 screws supplied in the accessory
bag.
6.
Plug the vacuum pump into the power source - the pump will start
automatically. Step on the base until it lowers and adheres to the work
surface.
7.
Tighten the four (4) leveling screws only enough to eliminate rock-
ing. Over-tightening can lift the gasket off the ground and release the
vacuum.
The vacuum gauge must read a minimum of 20
inches of mercury vacuum. To reduce the risk of
injury DO NOT CORE if the gauge reads less than
20 inches of mercury vacuum.
Filter Jar
Vacuum
Gauge
Coupler
Leveling
Screws
Vacuum
Line Cou-
pler
WARNING!