5. Commissioning, operation
5.1.1 Tightening torques for compression fittings
Sealing
Stainless steel ferrule
Stainless steel compression ring
PTFE ferrule
5.1.2 Tightening torque for M12 mating connector or M12 adapter
Choose a tightening torque of 0.6 Nm.

5.2 Electrical connection

The electrical connection is made via a circular connector.
Output signal Pt100 and Pt1000 (standard)
M12 x 1 circular connector (4-pin)
4 ... 20 mA
Alternative pin assignments possible.
For further information see order documentation.
Accessories: M12 x 1 Pt adapter to DIN EN 175301-803 angular connector
mA
M12 x 1 connector
WIKA operating instructions models TR31-3, TR31-K
Turns
Max. pressure in bar
1 ¼ ... 1 ½
100
1 ¼ ... 1 ½
100
1 ¼ ... 1 ½
8
Directly connected cable
2-wire
3-wire
4-wire
Angular connector
EN
red
white
red
red
white
red
red
white
white