Current Display
The output current indicates how hard your energizer is working. When your fence
is in good condition this reading will be low, typically under 15 Amps. As the load
on the fence increases the current will rise and output voltage will fall. The output
current will typically change with fence conditions, seasonal grass growth and wet
weather. A high output current, typically over 40 Amps indicates there is a very high
load or short circuit on the fence.
Voltage Display
Output voltage is an indication of how effective the shock is on your fence. It is
generally recommended to have 3KV or above on the fence at any time. If the output
voltage is too low there will not be enough voltage to 'break' through the animals
hide and deliver an effective shock.
Zone Indicators
The zone indicators show what zones are active on the fence system. The Energizer
zone (
) and Earth zone (
installing a combination of up to 6 Fence Monitors or Alarm Systems. See Accessories
(p.19).
Navigation Buttons
The navigation buttons allow you to view the performance of different areas of your
fence system. By pressing (<) or (>) you can scroll through the zone indicators to
view fence or earth voltage. The zone you are looking at is highlighted by the zone
indication arrow (
Standby Button
Pressing the standby button turns the energizer pulses on or off.
Settings Buttons
The settings buttons allow you to adjust the alarm levels and output voltage of the
energizer. Pressing the setup button (
setup mode. If no further buttons are pressed within 10 seconds the energizer
automatically exits setup mode and starts pulsing as normal.
Other Icons
The controller may occasionally display other icons for your information.
Energizer over-temperature: The energizer has detected that its internal
temperature is too high and has automatically slowed its pulse rate down. The
energizer may shut down until the temperature has decreased.
Settings mode: The user has entered the controller setup mode.
Standby mode: The energizer has been placed into standby and has stopped
pulsing. Press the standby button to resume normal operation.