SHOWN ON
AND
DISPLAY
SELECT
-4°C / +4°C
CL (0°C)
20°C/ 35°C
AH (35°C)
5°C/ 20°C
AL (5°C)
5/ 10/ 15
BL (10)
0,5°C/ 3°C
db (0,5°C)
ON/ OFF
Pro (oN)
4/ 6
Seg (6)
ON/ OFF
ES (OFF)
ON/ OFF
PP (OFF)
TO
DESCRIPTION
Change in the difference between the
displayed temperature and the current
temperature.
Maximum temperature that can be set.
Maximum temperature that can be set.
Time (in seconds) until entering power-
saving mode .
Hysteresis: difference in temperature
between the one indicated and the one
used to give the order to the boiler. It is
used to modify the on and off margin
to prevent turning on and off from
happening continuously, helping you to
save energy.
Turn on or off automatic programming
mode.
Programmed period with 4 or 6
daily slots.
Turn the smart function on or off.
This function lets the device order the
turning on of the boiler in advance so
that the desired temperature is reached
at the programmed time.
Turn the antifreeze function on or off.
With the device turned off, if room
temperature falls below 5 °C frost
protection mode be activated and the
boiler will start operating.
When the temperature reaches 8 °C it
will turn it off again.
36