NHT UL BL
4 - Remove the bowl gasket from its seat (see figure 9).
5 - Dismantle the faucet assembly (see figure 10).
6 - Slide the drip tray out and empty it.
5. 3. 2 CLEANING
ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source.
IMPORTANT
Do not attempt to wash any machine components in a
dishwasher.
1 - Prepare at least two gallons of a mild cleaning solution of
warm (45-60 °C / 120-140 °F) potable water and
8
figure 9
figure 10
dishwashing detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as too strong
a solution can cause parts damage, while too mild a
solution will not provide adequate cleaning.
IMPORTANT
In order to prevent any damages to the dispenser use
only a detergent suitable with plastic parts.
2 - Using a brush, suitable for the purpose, thoroughly clean
all disassembled parts in the cleaning solution.
ATTENTION
When cleaning the machine, do not allow excessive
amounts of water around the electrically operated
components of the unit. Electrical shock or damage to
the machine may result.
3 - Do not immerse the lighted top covers in liquid. Wash them
apart with the cleaning solution. Carefully clean their
undersides.
4 - In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
5 - Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to starting
the machine. Do not allow the unit to sit for extended periods of
time after sanitization.
1 - Wash hands with a suitable antibacterial soap.
2 - Prepare at least two gallons of a warm (45-60 °C / 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with
half a gallon of water) according to your local Health
Codes and manufacturer's specifications.
3 - Place the parts in the sanitizing solution for five minutes.
4 - Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
5 - Place the sanitized parts on a clean dry surface to air dry.
6 - Wipe clean all exterior surfaces of the unit. Do not use
abrasive cleaner.
5. 3. 4 ASSEMBLY
1 - Slide the drip tray into place.
2 - Lubricate faucet piston, inside auger and outer spiral (see
points A, B and C of figure 11) only with the grease
supplied by the manufacturer or other food grade