Installer: Inform the consumer of the
location of the gas shut-off valve

3. ELECTRICAL CONNECTIONS

Electrical Requirements
120 volt, 60 hertz, properly grounded dedicated circuit protected by a 15 amp or 20 amp circuit breaker or time delay fuse.
NOTE: Use of automatic, wireless, or wired external switches that shut off power to the appliance are not recommended for this product.
Grounding:
WARNING
Ensure proper ground
exists before use
The power cord of this appliance is equipped with a three prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit checked by a qualifi ed electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN
ADAPTER. DO NOT USE AN EXTENSION CORD.
A word about GFCIs - GFCIs are not required or recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCIs) are devices that sense leakage of current in a circuit and automatically switch off power when a threshold
leakage level is detected. These devices must be manually reset by the consumer. The National Electrical Code requires the use of GFCIs in kitchen
receptacles installed to serve countertop surfaces. Performance of the range will not be affected if operated on a GFCI-protected circuit but occasional
nuisance tripping of the GFCI breaker is possible.
INSTALLATION INSTRUCTIONS
Flex connector
(4
ft. max)
1/2
Adapter
Gas shut off
valve
Shock Hazard: This appliance must be properly grounded. Failure to do so can result in
electric shock.
Pressure
regulator
Black iron
pipe 4
"
1/2
90° elbow
Nipple
(may not
be needed)
or
" gas pipe
1/2"
3/4
Installer: Inform the consumer of the location of the
gas and shut-off valve
28
90° elbow
Black iron
pipe
Union
Nipple
Gas shut off
valve