Operation
7. Enter the refrigerant filling quantity.
Either use the value shown on the filling quantities sticker in the vehi-
cle and enter it using the keypad (8) and the cursor keys, or use the
AirConServiceCenter's database.
A
NOTICE!
If in doubt, use the value shown on the label in the vehicle.
8. Use the arrow keys to select the required vehicle and press ENTER
to confirm.
✓ If you press the "i" key in database mode, information on the oil
quantities and oil types appears in the display (7).
9. Use the cursor keys  or  to select whether the air conditioning
system has two connections (high pressure and low pressure) or
one connection (high pressure or low pressure).
Press ENTER to confirm.
✓ The fully automatic air conditioning service is started.
✓ After the air conditioning service has finished, you will be prompted to
disconnect the hoses (11) and (12) of the AirConServiceCenter from
the vehicle air conditioning system.
10. Disconnect the service hoses (11) and (12) and press ENTER to
confirm.
The service hoses will now be drained. The device is then ready for
further use.
11. Put the valve caps of the vehicle air conditioning system back on the
connections.
78
Personal DB
ALFA ROMEO
ASTON MARTIN
AUDI
AUDI A8 (4D_)
1994-11.1997
PAG ISO 46
WAECO CODE:
250cc
50cc
HP/LP PORT
HP PORT
LP PORT
ENTER-OK STOP-EXIT
g.
775
ml.
250
8887200001
8887200013
VAS6746B
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido