5. Press
. The display will automatically change to zero and the RUN indicator will
show to indicate that the program is running.
6. When the applied (or removed) weight exceeds the programmed amount, the alarm will
sound and the DONE indicator will flash on the display.
7. Press any key to stop the alarm.
8. To cancel the RUN mode at any time, press the
NOTE: The RUN mode can only be initiated from the SET mode. If you cancel the RUN
mode by pressing
restored) followed by
may program the SET mode without starting the RUN mode by pressing
the program set point. The new value will be saved until next time the SET mode is
activated.
can be used during the RUN mode similarly as described in the HOLD MODE
section. The REF-METER-OCTA-PLUS provides additional functionality when using the RUN
mode. Refer to the REF-METER-OCTA-PLUS User's Guide for details.
Tank Capacity Mode
It is often convenient to know the relative amount of material (i.e. refrigerant) remaining in a
container (tank). The REF-METER-OCTA's Tank Capacity Mode allows a continuous
display of the percentage of material remaining in a tank. In order to compute the
percentage accurately, the REF-METER-OCTA must be trained to know the weights of an
empty and full tank. To train the REF-METER-OCTA Tank Capacity Mode, perform the
following steps:
, and wish to RUN again, press
again. The display will be zeroed when the program restarts. You
REF-METER-OCTA User's Guide
key.
(the previous set point will be
after setting
9