Operation
8. To end the air conditioning system test, press STOP.
9. Close the HP quick connector and detach it from the air conditioning
system.
I
NOTE
If you have turned off the vehicle engine to uncouple the HP quick con-
nector, restart the engine and turn on the air conditioning.
✓ The following display messages appear:
10. To end the air conditioning test, press the STOP button.
8.8
Free selection
I
NOTE
The "Free selection" menu is used to perform air conditioning
servicing step-by-step. You can perform the same processes as in the
short selection menu, but also omit individual procedures. In addition, it
is possible to enter the values for each individual process using the key-
pad. You can also enter the vehicle data for the service report in this
menu.
The following three processes can performed individually in the "Free
selection" menu:
Recycling phase: extraction, recycling of the refrigerant, pressure rise
test, draining the waste oil.
Vacuum phase: evacuation of the system, leak test / vacuum check.
Filling phase: filling with fresh oil, filling of UV additive, filling of refrig-
erant.
104
Disconnect the HP
service hose from
the A/C system
ENTER-OK
Wait!
Recovery from the
service hoses!
Process completed
STOP-EXIT
ASC 2500 G LE / ASC 3500 G LE
EN