7. MAINTENANCE AND SUPPORT
WARNING: Before any repairs to the electric pump, check that the power supply is disconnected and that
it cannot be accidentally reconnected during maintenance operations.
WARNING: If the electric pump is used for hot and/or hazardous liquids, inform the personnel who will
carry out the repair. In this case, clean the pump so as to guarantee the safety of the operator.
WARNING: Repairing or having the electric pump repaired by personnel not authorized by the
manufacturing company means losing the warranty and operating with unsafe and potentially
hazardous equipment.
WARNING: Pay attention to discharged liquid so that it cannot cause damage to people or things.
The electric pump does not require any ordinary scheduled maintenance. If the user wishes to prepare a scheduled
maintenance plan, bear in mind that the due dates depend on the type of liquid pumped and the running conditions.
For spare parts and documents for maintenance, contact the sales and support service.
7.1 Replacing the Motor
For all versions of the pump with motor of rated power less or equal to 5.5 hp (4kW), first remove the coupling safety
casings to access the motor mounting screws (Fig.18). For all other versions, the motor mounting screws are easily
accessible on the exterior (Fig.17). The motor shaft must have a key drive.
Note: It is not necessary to carry out any operations on the pump shaft and motor shaft connection joints.
WARNING: Replace the safety casings where necessary; failure to observe these instructions may cause
personal injury.
7.2 Replacing the Mechanical Seal
The type of mechanical seal can be identified from the pump Identification Code Section
4.3.A and from Fig.13.
For the versions VR 3/5/9, follow the instructions in Fig. 9.
For the versions VR15/20/30/45/65/95 with motor power less or equal to 5.5 hp (4kW), follow the instructions
in Fig.10.
For all other versions with motor power less or equal to 5.5 hp (4kW), follow the instructions in Fig. 11.
Note: The mechanical seal is version K for standard EN12756, type U for VR3/5/9/15/20, and type B
for VR30/45/65/95.
8. DISPOSAL
The disposal of this product, or part thereof, must be executed using local public or private waste collection.
9. TROUBLESHOOTING
WARNING: Before any repairs to the electric pump, check that the power supply is disconnected and that
it cannot be accidentally reconnected during maintenance operations.
WARNING: If the pump is used for hazardous liquids, inform the personnel who will carry out the repair.
In this case, clean the pump so as to guarantee the safety of the operator.
For problems and possible solutions, consult Figure 19 troubleshooting table.