Troubleshooting - Craftsman 107.10265 El Manual Del Propietario

2 gallon oil free portable air compressor
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Problem
The compressor does not run.
The motor hums, but does not run or
runs slowly.
The fuses blow or the circuit breaker
trips repeatedly.
The thermal overload protector cuts out
repeatedly.
The air receiver pressure drops when
the compressor shuts off.
There is excessive moisture in the air
discharge.
Air is leaking from the compressor.
The compressor runs continuously
The compressor vibrates.
The air output is lower than normal.

TROUBLESHOOTING

Possible Cause
1. Loss of power or overheating.
2. There is no electrical power being
supplied to compressor or, the power
switch is in the OFF position.
3. A fuse has blown at the power supply.
4. A breaker has tripped at the power
supply.
5. Thermal overload open.
6. The pressure switch is bad.
7. Tank is full of air.
1. The voltage from the power supply is low.
2. The gauge wire or the length of extension
cord is wrong.
3. The motor winding is shorted or broken.
4. The unloader or check valve is defective.
1. The fuse size is incorrect or the circuit is
overloaded.
2. The gauge wire or the length of extension
cord is wrong.
3. The unloader or check valve is defective.
1. The voltage from the power supply is low.
2. A poorly ventilated room is causing the
motor to overheat.
3. The gauge wire or the length of extension
cord is wrong.
1. The connections are loose or leaking
(fittings, tubing, etc.).
2. The drain valve is loose.
3. The check valve is leaking.
1. There is excessive water in the air tank.
2. The humidity is high.
1. The hose connection is loose or
improperly sealed.
2. The air hose is broken or damaged.
1. The tank drain valve is open.
2. The pressure switch is defective.
3. The usage is excessive.
1. The compressor mounting bolts are
loose.
1. The inlet valves are broken.
2. The connections are leaking.
13
Solution
1. Check for proper use of extension cord.
2. Check to be sure the compressor is plugged
in and the power switch is in the ON position.
3. Replace the fuse at the power supply.
4. Reset the breaker at the power supply and
determine why the problem happened.
5. First unplugged the compressor and wait
until it becomes cool. Motor will restart when
cool.
6. Replace the pressure switch.
7. Compressor will turn on when tank pressure
drops to cut-in pressure.
1. Check the voltage with a voltmeter.
2. Use the correct wire gauge and length
extension cord.
3. Take the compressor to a service center.
4. Take the compressor to a service center.
1. Check the fuse or breaker at the power
supply is the correct size and type. Be
sure to use only time-delay fuses to avoid
overloading a curcuit, disconnect other
electrical appliances from circuit or operate
compressor on its own branch circuit.
2. Use the correct wire gauge and length
extension cord.
3. Take the compressor to a service center.
1. Check the voltage with a voltmeter.
2. Move the compressor to well-ventilated area.
3. Check for proper gauge wire and cord
length.
1. Check all the connections with soapy water
and look for bubbles. Tighten any loose
conections until the leak stops.
2. Tighten the drain valve.
3. Take the compressor to a service center.
WARNING
Do not disassemble
check valve while air is in tank - empty
the all the air out of the tank before
dissasembly.
1. Drain the tank to remove water.
2. Move the compressor to an area of less
humidity or use an air line filter to reduce
moisture discharge in the tank.
1. Ensure connections are sealed with thread
sealing tape and tightened.
2. Replace the air hose.
1. Ensure the tank drain valve is closed.
2. Take the compressor to a service center.
3. Decrease the amount of tool run-time; the
compressor is not large enough to supply the
air requirement of the tool.
1. Tighten mounting bolts.
1. Take the compressor to a service center.
2. Apply thread sealing tape to fitting and
tighten.

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido