Maintenance And Care; Troubleshooting - Dräger ABIL-R Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
Alternative C (supply from mobile compressed air source):
3
Like alternative A
4/11 such as ageing. A and if the compressed air supply hose is not part
of the mobile air source, connect it to the mobile air source
6
n/a
5
Like alternative A
7
n/a
*
activate mobile compressed air source
2
Like alternative A
1
Like alternative A
After use
Leave hazard area.
1)
1
Remove full-face mask
.
4
Disconnect compressed air supply hose:
Firmly press both coupling halves together and pull back outer sleeve
at same time until coupling disengages. Fit caps.
3
Undo waist belt.
Take off apparatus and turn off compressed air supply.

Maintenance and care

See "Maintenance intervals".
Clean, disinfect and dry mask.
For breathing hose:
Clean: Must be cleaned after every use. Do not use solvents, such as acetone,
alcohol, etc. Clean with lukewarm water containing the all-purpose detergent
2)
Sekusept Cleaner
and a cloth. Then allow to dry at room temperature.
Check correct functioning and absence of leaks
Assemble compressed air line breathing apparatus as described for
"Use". Without
and breathing hose.
mask
Start up compressed air supply system and check operating pressure
(required: 7 - 10 bar) adjust if necessary.
Brush the connections and screw connections with soapy water
when at operating pressure. No bubbles should form. Tighten seals
if necessary.
Function test:
The excess valve is integrated in the breathing hose which connects
the ABIL-R1/ABIL-R2 with the half or full face mask.
Close the control valve and seal the excess valve. A low volumetric
air flow must be noticeable.
Open the control valve completely. A high volumetric air flow must be
noticeable.
Storage
All parts must be stored in a dry, cool and dust-free place where they cannot be
deformed. Keep away from direct light and heat.
Observe ISO 2230 and national regulations for the storage, maintenance and
cleaning of rubber products.
Technical data
Compressed air hose
Compressed air supply hose
Respiratory air
Operating pressure
Temperature in use
Volumetric air flow
Min.
Max.
1)
Note the associated instructions for use.
2)
Made by Messrs. Henkel Hygiene GmbH, D-40554 Düsseldorf, Germany.
Note the associated Instructions for Use
Max. length 3 m
Max. length 50 m,
antistatic, heat-resistant
As per EN 12 021
Do not use oxygen or
oxygen-enriched air.
7 - 10 bar
–10 °C to 60 °C,
refer to "Use"
300 litres per minute
1000 litres per minute

Troubleshooting

Fault
Cause
Unpleasant taste
Respiratory air does not
conform to EN 12021
No air
Cylinder valve closed
Couplings not closed
Hose jammed
Air flow too low
Control valve turned
down
Operating pressure too
low
Hose too long
Filter contaminated
Air flow too high
Control valve open wide Turn control valve down
Operating pressure too
high
Maintenance intervals
Equipment
Work required
item
1)
Full-face mask
and breathing
Clean, disinfect, dry
hose
Couplings
Use a test gauge to check the
plug-in coupling for wear
Check that the couplings are
free-moving
Complete
Clean outside
compressed air
Rinse inside with air
line breathing
Check correct functioning and
apparatus
absence of leaks
Compressed air
Charge
cylinder
Check charging pressure
Expert testing
Pressure
Replace high-pressure
reducer
gaskets
General overhaul
Fine
Replace filter cartridge
compressed
air filter
1)
Note the associated instructions for use.
2)
e.g. by Dräger Safety
3)
Only if there is a smell of oil.
Remedy
Check all filters and
replace and smell if
necessary
Open cylinder valve
Check couplings
Check hoses
Open control valve
Set operating pressure
Check hose length
Replace filter
Set operating pressure
X
X
X
X
X
X
X
X
X
X
2)
X
2)
X
2)
X
X
3)
X