VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS

4
6
Optimal installation
1- Operator
2- External photocell
3- Flashing warning light
4- Antenna

TECHNICAL DATA

Max. weight of gate
Max. width of gate
Motors power supply
Motor power
Motor RPM
Condenser
Mechanical unlock for emergency manoeuvre
Working temperature
weight
Protection rating
Opening time 90°
Rod stroke
Force of thrust
motor current input
2
3
1
5
7
1
5- Internal photocell
6- Electronic control unit
7- Key-switch
8- Remote control
PM
(reversible)
1,80 (300) - 2,50 (400) - 3,50 (600) mt
12Vdc
50 W
900
/
/
/
-20° C / +55° C
15/25/30 sec
300/400
3 A
8
PM1
(not reversible)
250 Kg
230 Vac
250 W
800
12,5 µF
With key
7.5 Kg
IP 55
300/400/600
1500 N
1 A
5