CONSIDERATIONS FOR INSTALLATION
The installation and testing operations must be performed solely by qualified personnel in
·
order to guarantee the proper and safe operation of the automatic gate.
The company declines any responsibility for damage caused by incorrect installations due
·
to incompetence and/or negligence.
Before assembling the automatism, check that the gate is in perfect working order, hangs
·
well on its hinges and is suitably lubricated. It must also comply with the safety standards
in force in the country of installation..
1- Before fastening the brackets provided, establish the coordinates using the data given in
Table 1,
bearing in mind that they are valid if the operator is at maximum extension minus one
centimetre of the available stroke (CD) when the gate is closed to obtain maximum working
efficiency.
2- Data B in the table, with reference to the single values A, are to be considered as values
(recommended).
3- To anchor the piston, use the fastening brackets provided.
COORDINATES AND TABLE
1. Establish coordinates A + B that are
to be used.
2. Note: The stroke used (CU) of the
operator must never be equal or
greater than the available stroke (CD)
3. The sum of coordinates A + B,
establishes the stroke used CU .
TABLE 1
Opening angle
90° Available stroke = 400mm
90° stroke 600 mm
Note1: A+B = C
(Stroke used) C
U
INSTALLATION
90
100
110
= (Available stroke) = 300 mm /400 mm /600mm
D
A
B
80
80
90
90
100
100
100
150
110
110
120
120
120
100
130
130
140
140
150
150
160
160
175
175
190
190
200
200
300
300
Cu
160
180
200
250
220
240
220
260
280
300
320
350
380
400
600