Ultra high efficiency "green" battery charger
With up to 95% efficiency, these chargers generate up to four times
less heat when compared to the industry standard. And once the
battery is fully charged,
consumption reduces to 0,5 Watt,
power
some five to ten times better than the industry standard.
Durable, safe and silent
- Low thermal stress on the electronic components.
- Protection against ingress of dust, water and chemicals.
- Protection against overheating: the output current will reduce as
temperature increases up to 60°C, but the charger will not fail.
- The chargers are totally silent: no cooling fan or any other
moving parts.
CHARGE
BULK
ABSORPTION
FLOAT
TEST
Voltage
Current
OPT. RECONDITION
Reconditioning
A lead-acid battery that has been insufficiently charged or has
been left discharged during days or weeks will deteriorate due to
sulfation. If caught in time, sulfation can sometimes be partially
reversed by charging the battery with low current up to a higher
voltage.
Recovery function for fully
discharged batteries
Most reverse polarity protected chargers will not
recognize, and therefore not recharge a battery which has been
discharged to zero or nearly zero Volts. The Blue Smart IP65
Charger however will attempt to recharge a fully discharged
battery with low current and resume normal charging once
sufficient voltage has developed across the battery terminals.
The VictronConnect app
Setup, readout and configure your Blue Smart IP65
Charger via your smartphone.
You can display the status of your charger and
battery and even control the functions of your
charger using the VictronConnect app. On your
screen the readout of voltage and current is default
available.
Download your app for iOS and Android here at
https://www.victronenergy.com/live/victronconnect:start
STORAGE
STORAGE
1
Storage mode: less corrosion of the positive plates
Even the lower float charge voltage that follows the absorption
period will cause grid corrosion. It is therefore essential to reduce
the charge voltage even further when the battery remains
connected to the charger during more than 48 hours.
Temperature compensated charging
The optimal charge voltage of a lead-acid battery varies inversely
with temperature. The Blue Smart IP65 Charger measures
ambient temperature during the test phase and compensates
for temperature during the charge process. The temperature is
measured again when the charger is in low current mode during
float or storage. Special settings for a cold or hot environment are
therefore not needed.
Li-ion battery mode
The Blue Smart IP65 Charger uses a specific charging algorithm
for Li-ion (LiFePO₄) batteries, with automatic Li-ion under voltage
protection reset.
REFRESH
STORAGE
week