10 Troubleshooting
10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device.
The product warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
NOTICE
• Consult the documentation for the welding components.
Observe the attached "Warranty" document. In the event of any questions and/or problems, please contact your retailer or
the manufacturer.
10.1 Cleaning unit
Fault
Pneumatic motor does
not run
Stroke does not work
Insufficient cleaning
Torch parts are
damaged
Tab. 15
Troubleshooting BRS-LC
10.2 TSi injection unit (optional)
Fault
No injection
Too much/too little
spray mist
Too little spray mist
No spray mist
Tab. 16
Troubleshooting for the injection unit
EN - 22
Cause
• Compressed air supply/hose connection
interrupted
• Solenoid valve Y2 does not switch
• Valve actuator does not move
• Solenoid valve Y1 does not switch
• Reamer defective or blunt
• Wrong equipment parts
Cause
• Check the fill level
• Compressed air supply/hose connections
interrupted
• Mechanically operated injection valve Y4
does not switch
• Anti-spatter fluid is empty
• Metering quantity incorrectly adjusted
• Injection time too short
• Operating pressure too low
• Operating pressure too low
Troubleshooting
• Check all supply lines leading to the motor,
solenoid valve Y2 and threaded fittings
• Motor defective; replace
• Check the signal output of the robot control
• Replace solenoid valve
• Check the supply lines to the valve and
threaded fitting
• Replace the reamer
• Check torch-dependent parts
• Check the immersion depth of the torch
Troubleshooting
• Top up the anti-spatter fluid
• Check all supply lines leading to the
cylinder and threaded fittings
• Replace mechanically operated injection
valve Y4
• Replace or refill bottle
• Adjust the throttling screw
• Check injection time (torch dwell time in
injection unit)
• Check the operating pressure
• Check the operating pressure
BAL.0123 • 2020-12-15
BRS-LC