Remote control safety functions
Blocking protection
The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds
after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the
obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to
use the fan normally.
Note: Unless you remove the obstruction blocking the fan, it will not operate correctly.
Overload prtection
If the fan's receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the motor
will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote control.
Note: If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately. The
duration of the warranty is indicated in the warranty document provided in this manual.
Rotation direction: summer and winter options
The sliding switch controls the direction, whether clockwise or counterclockwise.
Summer option/down - or left-facing position (depending on the model) - The fan runs counterclockwise. The downwards air
current creates a refreshing effect as indicated in diagram A.
Winter option/up - or right-facing position (depending on the model) - The fan runs clockwise. An ascending air current
pushes hot air away from the fan area near the ceiling, as indicated in diagram B. This allows you to use less central heating.
Note: Turn off the fan, lower the differential, and wait for it to come to a complete stop before changing the blade rotation
direction with the sliding switch.
Balancing – Wobbling problems during fan operation
If the fan body wobbles during its operation, this is not a sign of malfunctioning (even if it wobbles a few centimeters). To
reduce wobbling, you can, while the fan is off:
1. Check that all blades are properly fastened by tightening their screws.
2. Check the distance between each blade and the ceiling. Measurements to the ceiling can be carried out as shown in the
following diagram. If variations exist and you have already correctly tightened the screws, check that all blades have the
same shape. If any of them have a shape that is visibly different, this may be causing an imbalance during fan operation