DIP6
With all DIPs on ON, the control unit switches to SERVICE MAN mode.
The PHOT input has the CLOSE push-button function (connect the button with N.O. contact).
The PP input has the OPEN push-button function (connect the button with N.O. contact).
The SWO and SWC inputs are deactivated.
The OPEN/CLOSE push-buttons must be kept pressed during operation. The opening of the
STOP input stops the motor.
The contemporary pressure of OPEN/CLOSE stops the motor.
When DIP1 is moved to ON, the board indicates that the torque has been applied during a
number of flashes (from 1 to 4) of the DL2 green LED, followed by a 3-s interval.
The max torque is indicated with DL2 green LED with fixed light.
To increase the torque, press P1. The DL2 LED changes the number of flashes to indicate the
selected torque value.
Once the desired torque is selected, move DIP 1 to OFF to memorise this presetting.
As soon as DIP1 is to ON, the DL1 red LED indicates whether the pre-warning flashing is
activated.
The pre-warning function can be activated or deactivated with P2 key.
LED DL1 On: Activated pre-warning, the indicator lamp switches on for approx. 3 seconds before
the motor starts.
LED DL1 Off. Pre-warning is deactivated.
The CORE control unit is equipped with a built-in radio module for the fixed or roll-on code of
remote controls, with 433.92MHz frequency.
To use a remote control, it is first necessary to store its code in memory. The memorisation
procedure is described hereunder. The device is able to store up to 64 different codes in
memory.
By pressing P1, the control unit enters the radio learning phase: DL1 red LED flashes 1 time per
second, awaiting the key to the matched to the Step-by-Step function;
When the key is stored in memory, exit from the programming mode;
By pressing P1 twice, the DL1 red LED flashes 2 times per second and the pedestrian learning
phase is entered (the pedestrian function controls an opening operation of 7s).
When the key to be matched is memorised, exit from the programming mode.
If the programming mode must be left without storing any remote control signal, press P1 key
until DL1 red LED starts to flash in "power on" mode (see LED diagnostics on page 7).
To reset the memory of the receiver, press and keep P1 and P2 keys pressed for around 10
seconds (during this period of time, both DL1 and DL2 flash rapidly).
After 10 seconds, when the two LEDs are switched on with fixed light, release the push-
buttons.
10
The programmable code transmitters are enabled or
disabled.
On: Radio receiver is enabled for roll-on code transmitters
Radio
only.
Off: Receiver is enabled for both roll-on and programma-
ble code transmitters.
SERVICE MAN MODE
ADJUSTMENT OF THE TORQUE (DIP1:ON)
PRE-WARNING ACTIVATION/DEACTIVATION
RADIO SELF-LEARNING (DIP1:OFF)