Installation
Remove packing sheet from the back of the sleeve, and
packing corner and blue tape from the air conditioner.
INSTALLATION REQUIREMENTS
If you use an existing wall sleeve, you should measure
its dimensions.
Install the new air conditioner according to these
installation instructions to achieve the best performance.
All wall sleeves used to mount the new air conditioner
must be in good structural condition and have a rear grille
to securely attach the new air conditioner. (FIG. 1)
Installing the FRIEDRICH USC sleeve ensures optimal
performance of the new air conditioner. (FIG. 2)
20-
3
/
"
32
(511 mm)
Air Conditioner
aluminum metal grille
FRIEDRICH Wall Sleeve
ELECTRICAL SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate (found on left side of cabinet).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections. SAVE CARTON
for storage and this OWNER'S MANUAL for future
reference. The carton is the best way to store unit
during winter or when not in use.
24"(610 mm)
14-
/
"
13
32
(366 mm)
15
18-
/
"(468 mm)
32
FIG. 1
25-
7
/
"
8
(656 mm)
15-
17
/
"
32
(394 mm)
16-
/
"
23
32
(425 mm)
FIG. 2
11
INSTALLATION HARDWARE
2
1
2 Size options
8
3
9
2 Size options
ITEM
NAME OF PARTS
PLASTIC GRILLE
VERTICAL INSULATION STRIP
AROUND INSULATION STRIPS
HORIZONTAL INSULATION STRIP
SUPPORT BLOCK
BAFFLE
TRIM FRAME
SHIM
PLASTIC NUTS AND WASHER SCREWS
GRILLE REAR
CAUTION
To avoid risk of personal injury, property damage,
or product damage due to the weight of this
device and sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
• Carefully inspect location where air conditioner
will be installed. Be sure it will support the weight
of the unit over an extended period of time.
• Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and
rear coils.
• Make sure air conditioner does not fall during
installation.
REQUIRED TOOLS:
• Tight Fitting gloves
• Standard screwdriver
• Phillips screwdriver
• Pliers
• Sharp knife
4
5
6
10
7
Q'TY
1
1
2
1
2
1
2
2
4
1
• 3/8-inch open end
wrench or adjustable
wrench
• 1/4-inch hex socket
and ratchet
• Tape measure
• Electric drill
• 1/4-inch drill bit