2.5 Operating conditions
i
Temperature range during operation: 0 to +50°C
Relative air humidity: 95% at +10°C not condensed
3.1 Settings and adjustments
!
The machine may only be operated with the flange head!
Rotate flange head clockwise
or counterclockwise to adjust
depth.
1 click is 0,125 mm up or down.
Safety lever
ON/OFF handle
EN
Recommended user supply:
Min. 25 CFM | 0.71 m3/min
Pressure 6.3 bar / 91 PSI max
Mounting a bevel head:
Push the locking button to lock the
spindle. Place bevel head and fasten
guide bearing tight with 4 mm Hex
wrench.
Locking button
Fiting 1/4"
High flow fittings recommended