7. Starting, operation

7. Starting, operation
Required tools: wrench (flats 19 and 16), screw driver (0.040" to 0.060" / 1 to 1.5 mm) and a pair of scissors,
allen key for WU-16

Mechanical connection

Don't use this
spanner flat
Use this spanner flat
for screwing in
Remove the protection cap only just before installation.
When mounting the instrument, ensure that the sealing faces of the instrument and the measuring point
are clean and undamaged.
Do not scratch or nick the bead. Do not over tighten. Damage to the bead will affect the fitting's perform-
ance and may cause leakage in the system.
Screw in or unscrew the instrument only via the flats using a suitable tool and the prescribed torque. The
appropriate torque depends on the dimension of the pressure connection and on the sealing element used
(form/material). Do not use the case as working surface for screwing in or unscrewing the instrument.
When screwing the transmitter in, ensure that the threads are not jammed.
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio WU-1X
Product label (example)
Signal
Power Supply
S# Serial No.
P# Product No.
GB
PIN assignment
7