Motor cooling fan inspection and cleaning
Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the vacuum cleaner is used in
a dusty place.
Tightness inspection
Hoses check
Check that the hose "A" (fig. 11) is in good condition and
correctly fixed.
If the hose is damaged, broken or badly connected to the
unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle plate
inside the filtering chamber.
Scrape the inlet from the outside and remove the deposited
waste as indicated in figure 11.
Cover tightness check
If the gasket "A" (fig. 12) under the cover "D" has become
slack, unscrew the screws "B" that lock the closing hooks "C"
in place and allow them to slide downwards until the deck "D"
closes perfectly.
Now tighten the locking screws "B".
Replace the gasket "A" (fig. 12) if the degree of tightness is
still not optimum.
Filtering chamber tightness check
If the gasket "A" (fig. 13) between the container and the
filtering chamber "C" fails to guarantee tightness:
-
loosen the four screws "B" that lock the filtering
chamber "C" against the vacuum cleaner structure;
-
allow the filtering chamber "C" to lower down and
tighten the screws "B" once it has reached the tightness
position.
The gasket must be replaced if it is torn, cut, etc...
Replace the gasket "A" if the degree of tightness is still not
optimum.
125/BDC1216/BDC1324/CV324/135/E-VAC1000
Vacuum cleaner disposal
Dispose of the vacuum cleaner in compliance with the laws
in force.
Proper disposal (electric and electronic waste)
(applicable in the European Union and in countries
providing a separate collection system)
The above symbol "I" (fig. 1), which is present on the product
or o in its documentation, indicates that the product can not
be disposed of with other domestic waste at the end of its
cycle of life. To prevent damages to the environment or the
health caused by improper waste disposal, please separate
this product from other waste and recycle it responsibly in
order to support the sustainable reuse of material resources.
Domestic users should contact the retailer or the local office
providing information on separate collection and recycling
of this product. Companies should contact the supplier
and check the purchase contract terms and conditions.
This product can not be disposed of together with other
commercial waste.
Wiring diagrams
Wiring diagram list 230 Volts
See fig. 15.
Name
J1
Anti-jamming filter
H1
Voltage plate indicator
S1-S2-S3
Motor switches
M1-M2-M3
Motors
Wiring diagram list 120 Volts
See fig. 16.
Name
H1
Voltage plate indicator
S1-S2-S3
Motor switches
M1-M2-M3
Motors
-9-
Part
Code
Z8 39533
Z8 39051
Z8 39000
4089100281
Part
Code
Z8 39051
Z8 39000
40000928
09/2014
GB