Program mode
º
C
Graph of selected
program
Decrease program
number
Program Options
Edit Program
This option allows you to edit or create a program.
First , you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting "-----" in the time parameter.
It should be taken into account that the regulation range permitted by the station is 150-450°C,
whereby it is not possible to create temperature ramps between room temperature (Toff) and
150°C.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and the program destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
14
P r o g r a m 8
Selected program
T e m p
º
C
380
Current temperature
Air
100%
Selected flow
Time 125s.
Remaining time
Increase program
number
Menu screen
Original PIN: 0105
M a i n m e n u
1
Reset settings
2
Station Settings
3
Program Settings
4
Counters
5
Program version
S e t t i n g s
1 Temp unit
Celsius
2 Maximum temp 450
C
0
3 Minimum temp
T OFF*
4 Fix temp
400
C
0
5 Temp Adjust
0
C
0
6 Max air
100%
7 Min air
10%
8 Fix air
40%
9 Time to stop
120 sec
10 Beep
ON
11 Pop up
ON
12 Change PIN
B a c k
* Selecting Minimum Temp to
"T OFF" allows for blowing at
ambient temperature.
C o u n t e r s
1
Station ON hours
2
Works hours
3
Works cycles
w w w.jbctools.com
E x i t
P r o g r a m S e t t i n g s
1
Programs
2
Edit program
3
Copy program
4
Delete program
E d i t P r o g r a m
º
C
S e l e c t
P r o g r a m
8
E d i t P r o g r a m 8
º
C
S t e p
T i m e
T e m p
A i r
E x i t
0
0
0
B a c k
4
2 0
4 5 0
1 0 0
15