Dr560 Tip Care; Mve Initial Setup; Mve Changing The Pump Filters; Removing The Pneumatic Tubing - jbc RMVE-C Serie Manual De Usuario

Estación completa de reparación con bomba neumática
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DR560 Tip Care

The intake tube should be periodically cleaned by the largest rod.
Important
DO NOT press the vacuum pump button while tinning the desoldering tip, as the fumes given
off by the flux would quickly block the ducts and the air filter.
Desoldering process
Use a tip with a larger diameter than the pad to achieve maximum aspiration and thermal efficiency.
1. Placing
2. Rotating
Place the tip with the
When the solder liquefies,
component terminal in the
gently rotate the tip so that
hole.
the compo nent terminal can
be lifted off.
After pressing the desoldering key there is a slight delay until the self-contained vacuum pump
stops. This makes sure that the vacuum circuit is completely empty. If any solder remains are left
on a terminal after desoldering it, resolder it with fresh solder and repeat the desoldering operation.
26
3. Aspirating
Press the vacuum pump
button long enough to remove
the solder.

MVE Initial Setup

After connecting the pneumatic desoldering module (MVE-A), enter the
Peripherals Menu and select the port which you want to join with the module.
Peripherals
1. Select the module from the list of
peripheral connections. Remember your first
connection is denoted as "a", the second
being "b", etc. (e.g. MVE_a, MVE_b,...)
2. Press Menu or Back to save changes.
Once set up, you can change the module
settings by entering the Peripherals Menu.
MVE Changing the
pump filters
- Use a damp cloth to keep the casing clean.
- Periodically check all cable and tube
connections.
- Keep filters clean to ensure proper solder
suction and replace them when
necessary.
Suction filter
Ref. 0821830
Cotton filters
Ref. 0781046
O Ring
Ref. 0007717
Spare filters
Filter cover
Ref. 0005966
Ref. 0004710
Important: Do not use sharp pointed objects to open the suction filter.
w w w.jbctools.com
17:14
Peripherals
Port 2-DR
Pedal
None
Module
Module
None
MVE_a
None
Removing the
pneumatic tubing
- Push the release ring to remove the
pneumatic tubing.
1
2
Release
ring
Escape filter
Ref. 0008446
27

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rmve-1cRmve-2cRmve-9c

Tabla de contenido