LIGHTING INSTRUCTIONS
1. Turn the knob on the LP cylinder valve
counterclockwise to the ON position.
2. Turn the Valve Knob on heater to the OFF position.
3. Wait five (5) minutes for any gas to clear. Smell
for gas. If none is evident, proceed to the next
step.
4. Push in the valve knob and turn to "PILOT".
NOTE: If this is first time use for heater or LP
cylinder has been replaced, hold the valve knob
for approximately 30 seconds to allow bleeding
of air from system then turn valve knob to PILOT.
5. While depressing the valve knob, press red piezo
ignition button to ignite. It may be necessary to
press the ignitor button several times to ignite
the center burner panel.
6. Continue to hold valve knob down for 30
seconds after the panel has lit. This will heat
the thermocouple. After 30 seconds, release the
valve knob.
7. If heater fails to light, or does not stay lit, repeat
Steps 2 through 6.
8. When the center burner panel stays lit, turn valve
knob to desired setting.
TEST FIRING HEATER
It is always a good idea to test fire your heater in
a safe and controlled environment, in an area with
adequate ventilation, and away from any combus-
tibles to be sure that all functions of the heater and
gas supply system are operating properly. Leak
test all gas connections with a 50/50 solution of
dish soap and water. DO NOT use a flame to test
for leaks!
SHUTDOWN INSTRUCTIONS
1. Turn the Valve Knob to the "OFF" position.
2. Turn the knob at the LP cylinder clockwise to the
OFF position.
3. Disconnect Regulator Hose assembly from the
LP cylinder.
MOVING AND POSITIONING THE
HEATER
There is a brake in each of the front wheels of your
heater that helps keep it in place when in use. To
engage the brakes, push the lever down on each
wheel. To move the heater, release the brakes, simply by flipping the levers on both brakes up.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
WARNING: THIS HEATER IS NOT INTENDED FOR RESIDENTIAL USE.
Propane Heater Manual
OPERATION
Off
Pilot
Low
Medium
High
13