7. Operation of Maximum & Minimum modes Speed Capture functions - mx,mn.
7.1.
Having selected the required mode, i.e. Maximum or Minimum, (mx).
7.2.
You are now ready to Capture a reading "On Demand" but continuing to operate normally.
7.3.
When a capture test is ready to commence, while the Measure button is held On, press
Programme button once, at this point the instrument will switch into high speed Timebase
mode, (0.1 Seconds) and will Capture the highest or lowest reading after pressing the
Programme button.
Releasing the On button will hold the reading and cancel the Capture mode until another
Capture measurement is required, when 7.3. should be repeated.
8. Count measurement mode - cnt
8.1.
Select mode as described in Measurement mode selection section
8.2.
For rev Counting optically, point the light beam at the target and the instrument will
measure all revs. (pulses) until button is released, the display will hold Count for 1
minute.
8.3.
By contact method, fit contact adaptor, press speed cone onto the end of the shaft, the
Instrument will count revs.
9. Linear Length Totalisation measurements - mt, ft, yd -
9.1.
Select any linear unit of measurement, press contact wheel onto moving surface and
commence Count by pressing & holding Measure button On, Count will increment until
button is released.
9.2.
The displayed value can be scanned through the equivalent values of Metres, Feet,
Yards, Count by pressing the Programming button, the instrument automatically calcu-
lates the appropriate reading.
Note. Measurement Units will be stored in originally programmed parameter e.g. metres.
10. Time interval measurement - int
10.1.
Select int mode through Measurement selection mode
10.2.
This mode allows measurement of Time between pulses from optical system (or contac-
tor).
10.3.
Optically the instrument will measure the time in seconds between pulses, useful for cy-
cle timing of reciprocating machinery.
10.4.
(Time in seconds per revolution), which equals reciprocal speed.
10.5.
Very slow speeds can be measured in this mode below 3 rpm.
11. Display orientation - Inverting function - All modes
11.1.
The instrument can be used through 180 deg. rotation (e.g. with the light beam pointing
downward into a machine), the display inverts so that normal reading can take place.
11.2.
The UP Button selects normal mode for optical and contact measurements.
11.3.
The Down button selects the display inversion mode and the whole display including rel-
evant icons will reverse through 180 degrees allowing access to difficult applications.
Temperature specification and storage (LCD Display)
Operating temperature =
Storage temperature
0 to + 50 º C.
= –10 to + 80 º C.