with automatic closing enabled, a sequence of open/close commands causes the gate to
2
On
OPEN-CLOSE-OPEN-CLOSE etc (see also dip switch 4).
in the same conditions, the same command sequence causes the gate to OPEN-STOP-
Off
CLOSE-STOP-OPEN-STOP (step-by-step).
during opening, the photocell cuts in to stop the gate until the obstacle is removed. When
3
On
the obstacle is removed the gate resumes opening;
Off
during opening, the photocell does not cut in.
the open-close pushbutton reverses the direction of movement of the gate even while it
4
On
is opening.
NO-REVERSE function activated; the gate ignores the closure commands during open-
Off
ing and reversal of movement occurs only during closure;
5
On
the pre-flashing function enabled.
Off
the pre-flashing function disabled.
6
On
the "photocell test" function is enabled;
the "photocell test" function is disabled. Note: to be used when the photocells are not
Off
used.
7 - 8 2
RADIO CHANNEL operation (terminals no. 16 - 17)
nd
Dip 7 Dip 8 Function
Off
Off
Off
On
On
Off
On
On
9
On
RESISTIVE SENSITIVE EDGE (terminal no. 1);
Off
FIXED EDGE (NC contact – terminal no. 1);
10
On
the memorization function is enabled for self-learning of the travel;
leave the dip-switch in this position when the memorization procedure has been com-
Off
pleted.
K120M CHARACTERISTICS
LED - DL3
The LED, besides indicating that the power supply is connected, also signals errors with a series of
pre-defined flashes:
steady light:
normal operation;
1 flash:
buffer battery voltage lower than 17,3 V DC;
Check the mains power supply, charge the battery, replace the battery;
2 flashes:
phototest error;
Disable phototest (dip-switch 6 OFF), check operation and connection of photocells;
3 flashes:
power failure;
Check the thermal-magnetic circuit breaker (upstream from system), check the fuses;
4 flashes:
max current limit exceeded;
Gearmotor has exceeded absorption limits, check for obstacles across the path of the gate, check the
current absorption of the motor when loadless and under load;
18
Gate contact open: The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It deactivates
once the gate has completed its closure movement.
Bistable function active: the radio control impulse causes the contact to activate
and remain active until the subsequent impulse.
Monostable function active for 2 sec.: the radio control impulse causes the
contact to activate and remain active for 2 sec.
Monostable function active for 180 sec.: the radio control impulse causes the
contact to activate and remain active for 180 sec.